  1. F

    Room Thermostat not working

    forget looking in the boiler manual, the gas valve that you are stating is NOT! the problem with your system. the motorised valves will normally sited next to the pump.
  2. F

    Room Thermostat not working

    sounds like a faulty microswitch or actuator on the central heating zone valve,or a partially seized ch zone valve body.
  3. F

    Potterton Netaheat 16-22F dead

    get the rgi back and ask him to test if the aps has stuck on open circuit,also ask him to test the boiler stat for continuity across it terminals. in my opinion these are pretty basic faults that are easy to test,why have three engineers failed? :roll:
  4. F

    plumbed in kettle - is there one

    heres one, very expensive though. http://www.simplykitchensinks.co.uk/index.asp?SKSID=840&ItemID=1676
  5. F

    Drawbacks of sealed system?

    if the boiler is 15 to 20 years old it may not be suitable for a sealed system.
  6. F

    triton spellbind shower cold

    are you using the head supplied with it? a different head will not slow the flow down enough to heat the water.
  7. F

    Shower Screen for bent wall

    can't you just slice a slot into the bottom tile with a small grinder,that way the wall rail will fit flush to the wall
  8. F

    Water in expansion tank always hot?

    is water flowing out of the vent pipe when the pump is turned up? if thats so ,you have a problem with the layout of the feed and vent where it connects to the system. a system that is pumping over will sludge up very quickly. sounds like that is why the system needed cleaning in the first place.
  9. F

    Potterton boiler - heating / lockout

    there should be a external bypass fitted to this boiler,has it been closed? this would give the problems you are describing.