  1. A

    Condensing boilers regulations

    Exemption code 888 (or 8888) on the online registration thing. Not allowable after 30th June.
  2. A

    no mid position valve wiring on the s plan wiring diagrams .

    Personally I like the bringing the white wire into play quote, sort of dots the i's and crosses the t's doesn't it?
  3. A

    wiring wireless programmable stat

    Or replace the programmer with a cheap single channel timeswitch for simplicity.
  4. A

    no mid position valve wiring on the s plan wiring diagrams .

    yes!!!! http://content.honeywell.com/uk/homes/systems.htm
  5. A

    wiring wireless programmable stat

    The RF3 will only control heating, not hot water. Therefore the room thermostat and heating switched live need tio be removed - what don't you understand about that?
  6. A

    wiring wireless programmable stat

    Terminal 3 on the scr to the white wire on the 3PV. Disconnect existing room stat and heating on from programmer and just use hot water side - I think.
  7. A

    Goldman & Sachs

    I think you'll find the prevailing attitude of everyone who is not a plumber or a heating engineer is that they were generally in the non-exam stream at school and were too thick to do anything else. Mind you I've met a few of those.....
  8. A

    Central heating boiler will not light

    Gonna have to. Am I right in thinking this BBU needs a special TC and a universal won't fit?
  9. A

    Draining and Re-Filling Combi System

    Turn off all rads except the one you want to move. Attach hose to drain-off and open. Vent the to-be-moved rad until the hose stops running. You have now drained the pipe work and the one rad. Move the rad to wherever you want. Find your filling loop and slowly open and watch the pressure...
  10. A

    banging pipes - Is it my toilet system?

    Try fitting a flow restrictor in the inlet valve. You haven't just been converted from gravity cold water to mains pressure by any chance have you?
  11. A

    combi boiler problem, please help

    Depends on whether it was the DHW pipe or the flow/return pipe. If you managed to solder a joint on then there couldn't have been much water in the pipe anyway. Why not just try bleeding the rads anyway, it only takes a few mins :)
  12. A

    Laying copper - price per metre

    I'm hopeless at pricing and need to wise up a bit, so, sorry if this sounds a bit nosey but I would appreciate some advice ...... Can I have your thoughts on standard pricing to run 15/22mm surface and underfloor? does this include soldered fittings or not? if not what is a normal standard...
  13. A

    What to ask when getting a CH installation quote

    I believe he was referring to the time it takes to powerflush a system.
  14. A

    British Gas quote for new boiler

    Make your email address and area visible and you'd probably get some decent quotes - just a thought :) _______________________ moderator bad thought :(
  15. A

    Back boiler conversion

    What "savings" exactly?
  16. A

    Expansion vessel for Baxi Combo 105e

    Not unless you can check it with a vacuum cleaner - preferably the customers!
  17. A

    Old towel rail - how to attach to c/h?

    Take it to a decent plumbers merchant - they'll have someting that will fit.
  18. A

    I AM SO DEPRESSED WITH THE GAS GAME

    Yeah but apart from that is it all going OK? :D
  19. A

    Wireless CH timers....?

    I used to fit Drayton digitsat 3's which are fine. Last week I fitted a Honeywell 7 day roomstat and it's the dogs doodahs - party button, next day off button, I'm away for the next xx days button - 45 quid.
  20. A

    running gas pipework for hob and gas cooker

    The best way is to get a corgi bod in to do it :D