  1. A

    problem in installing electric shower

    You must open the bleed screw to purge the air and prime the pump. Full instructions here .... http://www.tritonshowers.co.uk/installation/pdf_2/1-existing/T90si_UK_Guide.pdf
  2. A

    Emergency pump advice

    I was thinking more of something like a smallbore flexible pipe that I could use to suck up from anywhere - e.g. after stuffing down the DHW outlet of a HWC etc. Mind you, the self cutting W/M feed sounds OK, just whack it onto a hosepipe and away you go.
  3. A

    Emergency pump advice

    I've had a few jobs lately where it is necessary to drain down tanks, cylinders etc but have found that the drain offs are either not fitted, don't work at all or work very slowly. Usually I would syphon out but am looking for a faster method. I've tried those drill attachments and found them...
  4. A

    Odd heating / hot water system

    Come on! some of you brainboxes must be able to help! :D
  5. A

    CH newbie help - gravity or pumped?

    How did you create that schematic?
  6. A

    The Law and Radiator Thermostats

    As far as I know, it's now compulsary under part "L" to upgrade all controls when "carrying out work". How many customers would stand for it though? none that I know of. "Change your room stat madam?, certainly, I room stat, 6 TRV's, 1 new factory lagged cylinder - £700 all in"
  7. A

    Odd heating / hot water system

    Hi Have to go and replace a couple of 11" heaters in central London tomorrow evening. The owner has sent me some photos of his setup. We have successfully established over the phone that he has voltage to both heaters and both are open circuit. It appears to be a thermal store system...
  8. A

    Hot Water Options - Likely Fall in Mains Pressure

    All of the unvented cylinders that I've put in have had pressure reducing valves supplied set to 3 bar, so I wouldn't worry too much about being reduced to 2.5. So what if you can't run 2 showers similtaneously? you'd soon run out of hot water anyway!
  9. A

    Digital room thermostat

    There won't be straight swap but it's easy enough to do. From what you describe the existing stat is switched on via the programmer which in turn sends power to the valve. It doesn't sound like it goes back to the wiring centre, but as I can't see it then obviously I don't know. The existing...
  10. A

    Digital room thermostat

    Did you buy a programmable thermostat or just a stat? You are attempting to replace a 230/240V stat with a volt free relay which means you are going to have to do a bit of work to get it working. If it's just a digital stat then you are going to have to use the relay to provide a switched...
  11. A

    Flexible hose connectors

    I've been caught like this before and have gone out and got a 3/8 to 15mm connector and then found the supplied one in the bottom of the box! - check the packing again :)
  12. A

    Combi install? Corner cutting?

    Ensure that a roomstat suitable for a combi is fitted. Ensure that all all rads except that closest to the stat have TRVs fitted Check the docs for flue installation compliance
  13. A

    ferolli 77ff boiler fault

    Usually it's the APS which is next in sequence after the fan. You shouldn't really be doing this yourself though .........
  14. A

    Poor mains pressure

    Your easiest solution might be to put a large(ish) capacity cold water cistern in the loft and pipe this up to the boiler, attaching a single impeller pump. This would give you decent hot water pressure without having to do too much major re-plumbing work.
  15. A

    Bang smell of gas wet pants

    Shouldn't that be .... "smell of gas, bang, wet pants" ?
  16. A

    swaped cylinder now water wont circulate ????

    Sorry to accuse you of trolling bmx, my suspicious cynical nature :D P.S. The g3 exam is by far the easiest examination in the world to take, easier than getting an A* gcse (according to the daily mail)
  17. A

    swaped cylinder now water wont circulate ????

    That's odd. I could swear that I put down 15 litres on my exam paper :)
  18. A

    swaped cylinder now water wont circulate ????

    For goodness sake, can't you recognise trolling? :D :D :D :D :D
  19. A

    swaped cylinder now water wont circulate ????

    So presumably with just HW the boiler will either trip out or shut down in a matter of seconds? if not, the heat must be going somewhere - is there a bypass on your system anywhere?