  1. S

    baxi combi installing a digital timer

    blue to 2,brown to 1 , 2blacks to 3 and 4, job done, nothing in 5
  2. S

    powemax 115x..low water pressure..HELP PLEASE

    phone baxi, potterton let them sort it out,, fault on expansion vessel and change prv at the same time,, not many engineers will work on these boilers , good luck,, and its a common fault .
  3. S

    BAXI SOLO 24 HE LOUD WINEING NOISE

    system requires cleaning,,,,,
  4. S

    noise Promax 24/2 Boiler

    system requires cleaning.
  5. S

    Baxi solo 2 overheat

    Is the pump overun working ok,,Is the tank dry in the loft,, blocked feed pipe to heating,, just a few more things to check :wink:
  6. S

    BAXI 105E - CH pressure going too high

    Their are no 105e just over 2 years old , must be about 7 or 8 years old, baxi finished makin em years ago , unless its the 105 HE , Anyway if you have water coming out the shreader valve instead of air the expansion vessel requires replacing, fit anew one or fit an external one ,job done :lol:
  7. S

    Potterton Suprima 30

    Sounds like sludge in heat exchanger, get some c,h cleaner in.
  8. S

    Heatline Expert - anybody?

    Time to stick up for the decent gas engineers, sick of hearing about folks that have no clue at all how to repair boilers telling a registered gas safe engineer his job...... Like it has been said you should ask for a quote to repair and do not hand any money over till its fixed,,,,,simples...
  9. S

    Baxi Combi 80e

    You will need new 3/4 fibre washers new 1/2 fibre washers and new o ring for bypass pipe, and be gentle with the primary flow pipe that goes upto the main heat ex,,,, may leak
  10. S

    Potterton Promax HE Plus

    Used to just change the pcb, have had e168 reversed polarity as well, My cure at the moment is fit new pcb and gas valve solenoid not been back to any with the same fault , :)
  11. S

    BAXI Duo Tec Combi

    Duo tec , is a ace boiler but will suffer from time to time with the odd fault as will any other boiler from any other leading manufacturer, People try and compare them with back boilers that lasted and never broke down, we live in a different world nowadays :)
  12. S

    main 24 he combi boiler.

    Yes it does , refer to manufacturers intructions.
  13. S

    Megaflow overflow pipe dripping

    could be a couple of things, air bubble requires recharging, make sure if you have mixer taps fitted that the hot and cold are not mixing inside the tap, if you have rechrged the mega flo that the t and pr valve is not faulty by not shutting off correctly, I personally think that the mega flo...
  14. S

    baxi 105e leak

    just drain the boiler to do the job, and get new 3/4 washers ready for the new valve.
  15. S

    baxi 105e leak

    Depends what you want to pay,,, You can get a kit to do the job but i would get the whole valve, if one parts leaking like that you can bet the whole valve is ready to go.
  16. S

    Kitchen Tap - No Pressure

    sounds like the spindle has seized up, they cost 99p from wilkos
  17. S

    Question about our new boiler installation

    Think its page 15 in manufacturers instructions, installer should always fit mini expansion vessel and check valve to stop this fault occuring.
  18. S

    Main Combi 30 Eco

    Main eco 30 is a cracking boiler, wellworth the money and has totally different heat ex to the duo tech, all you have to do is carry warranty on after the guarantee runs out and your quids in :D happy days
  19. S

    potterton netta heat 16-22 MK2 F

    oh and plenty of asbestos in it,,,,,,,,,,,,,,,,,beware
  20. S

    potterton netta heat 16-22 MK2 F

    Give it a good funeral and stop messing with the unmessable, time to renew.