  1. S

    vaillant or viessmann

    Time to stick up for the baxi here,, Fit them, and know alot of good lads that fit them and wouldnt go for nothing else,, Boilers break down no matter what manufacturer.
  2. S

    Baxi 80 HE combi no hot water or CH

    diverter problem,, ie one of the pins sticking on the valve,, not an easy repair get some insurance on it ,, it could be costly to get it fixed correctly, not worth trying to sort it on your own ,wear and tear fault
  3. S

    BOILER LOCKING OUT

    Check the wiring as well , pump should be wired back to boiler
  4. S

    Potterton Performa 28i!! Please HELP

    vessels on the instant have a really bad habit of spliiting, putting water into air side, so its boiler off wall or external vessel time
  5. S

    Potterton Performa 28i!! Please HELP

    Thing is ,,,, new boilers break down as well,, but still good advice
  6. S

    Potterton Performa 28i!! Please HELP

    replacing the prv doesnt cure the pressure problem, the expansion vessel has worn out, This is the pressure problem .I would fit an external vessel and new prv Run the hot tap and see if the pipe to the heating starts warming up or even getting hot underneath the boiler , you may find diverter...
  7. S

    Powermax 155x

    sometimes insurance pays to have it,
  8. S

    Baxi combi instant 105e

    diverter valve assembly requres changing, part 248727and 248728 ,not a nice job,and could be expensive,while your at, it the expansion vessel will need recharging or fit an external one, get some pump seals ready and watch other fittings and components for leaks,
  9. S

    Powermax 155x

    Random lockout,,,,, First replace gas valve,then pcb, then check turbulators ,,then electrodes,,intermittant lockout could be either one or more than one thing, depending what work you have had done before,, do not do it yourself and always change burner gasket..Get heateam back , have the...
  10. S

    Baxi Solo 15HE - whistles after 5 mins from starting

    Sounds that come from that area are more often due to muck in the heat exchanger, even if its only a year old, I bet the noise was not their on day one,
  11. S

    Baxi Combi Condensing 133HE boiler not giving enough DHW?

    Could be faulty diverter cartridge, run the hot water only and see if the c/h flow pipe warms up as well,ie taking some of the heat from the hot water side,
  12. S

    Baxi Bermuda 401 'Popping'

    First time i heard this noise, Found that the burner had small cracks round the burner jets , so you could check the burner holes for wear and tear ,
  13. S

    BAXI 105e Instant hot water light not going out

    Hi is the boiler a 105 e or a 105e instant their is a big difference, you mentioned pre heat so i assume its the instant. Their could be a couple of faults , could be the diverter pin not working correctly so the pre heat is always going down the heating pipe and not getting upto temperature or...
  14. S

    Baxi Solo 2 30Pf - Constantly Fires Up ! - Help Required

    sounds daft but just change the pcb theirs nothing else on the boiler
  15. S

    Potterton Performa DHW/CH Problem

    Hi, to tell if the boiler can modulate at all go to the gas valve and chek with manometer that the burner pressure is at 12 mbar when hot tap running then disconnect a modulating wire it sits next to another wire at front of valve and then read what you have got ,it should be about 2 mbar ...
  16. S

    Noisy on producing hot water - Baxi Combi 133HE Plus

    Check the pressure in the expansion tank should be 1 bar, you can only check it with the boiler drained down, fit new prv valve , clean the return filter to the heating and if that doesnt cure noise fit new or clean hw plate heat exchanger,,, only drain boiler by valves underneath never by...
  17. S

    baxi 80 eco rads heating when only hot water requested

    YEP Its the diverter valve , you might as well take out baxi insurance on to get the work done as its probably as cheap as getting someonre from yellow pages
  18. S

    'new' error code on potterton

    pays your money for numerous parts to try and cure the problem
  19. S

    'new' error code on potterton

    yeh by the time you have done , it will be cheaper to get heateam in to do the job
  20. S

    Baxi combi boiler 105e rads wont turn off

    Change the whole diverter valve to be sure and make sure you have some new fibre washers and o rings ( about 45 mins)