    Replacing Bath Mixer Tap Unit

    Shouldn't be a problem. I try not to use silicon on taps if I can help it. Now would be a good time to fit isolator valves if not fitted. If fitting tails make sure the pipe your connecting to is nice and square/no sharpe edges. Hope this helps rob
  2. R

    "White" noise from central hetong

    You may want to check the feed/expansion tank in the loft as the float valve may have become stuck? Or they may be sludge in the bottom of the tank, not allowing water to refill the centeral heating system. Hope this helps Rob
  3. R

    "White" noise from central hetong

    What is your system? Backboiler/combi
  4. R

    restart after magnaclean

    Is open/closed stamped on the valve body? I think they should be horizontal? Don't forget to bleed after. Hope this helps Rob
  5. R

    push button toilet flush

    If you drain the cistern below the level of the seal, and get some food colouring and see if water is still passing into the toilet. If it does you will know its not the drop seal and it will be the seal at the bottom of the cistern. If so carefully turn the unit clockwise a touch which...
  6. R

    push button toilet flush

    Open the lid to the cistern and check that the siphon is fully locked into place. as they can sometimes become a bit loose or from improper fitting.
  7. R

    One cold radiator - tried everything!!

    I would drain the system down and leaving the drain valve open with a hose attached. Attach a hose pipe to the blocked pipe work and try using the main pressure to try and clear the blockage.
  8. R

    One cold radiator - tried everything!!

    Is system plumbed is plastic or copper? What size is the pipe work?
  9. R

    One cold radiator - tried everything!!

    Yes test both sides, Trv and lockshield. If they both flow, there must be another problem within the system. Hope this helps rob
  10. R

    One cold radiator - tried everything!!

    Turn the valves off and remove the rad and flush through with a hose. Remember to switch off combi. Get a bucket and slowly open one valve at a time, to see if they are blocked. Hope this helps rob
  11. R

    One cold radiator - tried everything!!

    Does the flow pipe to the radiator get warm?
  12. R

    Water Coming very slowly through mixer taps

    What was the flow like on the cold before the new installation? Are the isolation valves turned fully open if fitted?
  13. R

    8mm to 15mm towel radiator help

    Nice waste pipe 😮
  14. R

    Drain down sealed system

    If your rad is in the ground flow you will need to drain down the whole system. You can flush each rad individual by closing all the valves to the others, and leave the valves open on the one you want to flush, and turn the water supply and top up to 1 bar. Bleed the rad you want to...
  15. R

    Drain down sealed system

    Yes turn the boiler off. You don't need to open all the valves. Unless your going to flush the system through. Drain down system so your able to connect up the new radiator. If its on the first floor drain just below the working level. Wrap the PTFE around threads going into the...
  16. R

    mira sport electric shower

    I would take a picture of the insides of your shower, making sure it's switched off. And have a look down at your local DIY store and ask, if they can open one up, on display or box to check. Hope this helps Rob
  17. R

    Any top tips on flushing the system

    I would go with your first idea, but running the system first to warm up wont hurt. Make sure you open all the lockshield valves and Trv's if fitted to fully open to help get the muck out. Hope this helps Rob When you open the lockshield valve write down on a bit of paper, how many...
  18. R

    Is there a piece missing from this shower trap?

    I believe you need a minimum seal of 50mm to pass building regs. Is it possiable to fit another low level trap a bit further down the line? If its tight on the existing waste outlet. Hope this helps Rob 😃