Search results

  1. P

    vaillant combi boiler - shower too hot - low pressure?

    Probably because the incoming cold water is now at a higher temprature. The lower flow rate through a shower will give a higher temprature just turn the boiler hot water down and see what happens. When it is cold outside again turn it back up because the incoming water will be a lower temprature.
  2. P

    Landlord certificate question

    Your appliances are deemed safe at the time of inspection it is not a guaranttee that nothing can go wrong. Your car has an MOT every year but if your brakes did not feel right six monthes later who is responsible. It is the owner of the car, it is the same for your gas appliances. You have...
  3. P

    Please Help 100cm2 Air Vent for Back Boiler???

    Same question as gas_man what back boiler do you have?
  4. P

    Please Help 100cm2 Air Vent for Back Boiler???

    If the regs say 100cm2 then that is what you need, if you fit the vent without the baffle you are OK however I always fit the black hole so you comply with the regulations and still have anti draft if I remember correctly BM720.
  5. P

    Baxi Bermuda Inset 3 50/3 Problem

    Sorry to say that your problem needs to be sorted by a Gas Safe person.
  6. P

    ravenheat rsf82e- Little red 'valve cap' on top of boiler??

    It needs to be loose as it is your auto air vent
  7. P

    Vaillant VCW 242 pressure loss

    It points to your expansion vessel low on pressure and yes it is the red vessel. The other part on the right you have pointed to is your auto air valve. If you look in the FAQ you will find a question on the expansion vessel by chrisr you need to read that.
  8. P

    22mm pipe leak - reducer required?

    Hope all goes well
  9. P

    22mm pipe leak - reducer required?

    Just had a quick look and cannot see any. don't know about maybe B & Q
  10. P

    22mm pipe leak - reducer required?

    Pushfit on imperial 3/4 NO
  11. P

    22mm pipe leak - reducer required?

    Plumbers Merchant will stock both end feed or solder ring.
  12. P

    22mm pipe leak - reducer required?

    The old pipe will probably be 3/4 imperial you will need a 1M fitting 3/4 to 22mm cut the pipe before the leaking elbow and renew to the bath or cut out the leaking elbow at each side and use 2 x 1M 22mm tube and new elbow.
  13. P

    Washing Machine in very close proximity to Combi boiler.

    Common sence is that if the boiler is affected by the vibrating washer the possibilty of loose connections may affect the pcb or worse couse damage I am with you why take the risk however the custard always knows best.
  14. P

    Baxi potterton solo 15HE question

    No its not and it would point to a fault with the wiring. If you are not confident of doing electrical testing then get someone to locate the fault.
  15. P

    Baxi potterton solo 15HE question

    You can set the tempus 7 on auto for water and/or heating if you have not got the user instructions you can get them off the Drayton web page.
  16. P

    Radiator cold - cutting into pipe question

    It may be safer to roll the carpet back from under the radiator so if you spill and black water it is on the floor not the carpet. Block up the radiator holes so you don't spill on the way out :oops:
  17. P

    Radiator cold - cutting into pipe question

    Try the bucket you will see what sludge comes out.
  18. P

    Radiator cold - cutting into pipe question

    Yes but it is better to have a hose fitted then you can open the valve fully and let it run out faster and longer to move the sludge out of the pipe.
  19. P

    Radiator cold - cutting into pipe question

    Turn the radiator valves off at both ends of the rad then remove the radiator taking care not to spill the water on the carpets. Flush out the rad with a hose pipe to clean it out. Put a hose on the radiator valve, open the valve and flush the pipe. Do the same on the other valve and pipe. Fit...
  20. P

    Hot water pipes

    I have never upgraded to 22mm to feed a wash hand basin only. If you fit isolation valves fit full flow valves and you will be fine. Remember it is only a wash basin not a bath or a power shower. :wink: