  1. B

    plumber competence reprised

    May be he meant the unvented D2 should be 28mm?
  2. B

    Water Meters

    They usually read to .001 of a cubic meter!
  3. B

    Logic Combi 24 error F1 (Low Water Pressure)

    There could be various reasons. Check all your radiators for signs of leak. Check on the outside of the wall that the boiler is on to see if there are any signs of water coming from the little copper pipe out there.
  4. B

    Hepvo trap inline adapter/ bent adapter

    What do you mean by 'bent'? Maybe a standard P trap is what you want?!
  5. B

    Underfloor Heating

    I always install polyplumb's system where possible. They will spec and draw your requirements if you contact them via their web site. they are always helpful.
  6. B

    Do I need a 2nd hot water tank to support 2nd power shower?

    Get one, larger unvented hotwater cylinder put in to feed both showers and get rid of the pumps.
  7. B

    glow worm 30 cxi fan problem

    You may have a plate heat exchanger blockage. This is something you can check yourself. Instructions are in the manual.
  8. B

    Need a Concealed Cistern Recommendation to fit a 400mm unit

    Not something that someone often asks for a recommendation on!! and can't really recommend. Pop down to your local merchants and have a look. I fitted a PTS tradesave one the other week for someone - seemed fine to me; but now you can't see it!!
  9. B

    plumbing in a colonic irrigation tank

    The one I did was a 50 litre collection tank fed via a shower mixer to control temp. Usual air gap requirements between outlet and collection tank, then water for the irrigation was just via gravity to the a*se!
  10. B

    Gas Hob Connector

    You are clearly not competant to do this - let alone an RGI. You are incorrect on all counts; get an RGI to do it.
  11. B

    Gas Hob Connector

    A hob should have a rigid connection. You can't do it.
  12. B

    Room thermostat not responsive and Boiler/CH advice

    Don't worry about finding existing old wires, get your man to fit an RF stat. I would think the warranty is up now anyway. It would be good to think that once you've had a local chap sort it out you kept him on to look after the boiler in future. Forget BG.
  13. B

    Changing and teeing into Flow & return pipe

    Replace it with an ABV and adjust it correctly. Of course this is a small part of the work required to arrange your system as it should be...!
  14. B

    Changing and teeing into Flow & return pipe

    Does the bypass have an auto bypass valve or just a gate valve?
  15. B

    Using a pump with a Combination/Fortic cylinder

    There may well have been other people asking the question but if you look at your own "evidence" you will see that it is generally not advised. What you decide to do is up to you but my advice, and that of others, as you have conveniently pointed out, is: don't do it. So to other potential...
  16. B

    Using a pump with a Combination/Fortic cylinder

    "In case someone finds this thread later on"!! A quick look at the installation requirements of either of those pumps will tell you that your combi cylinder is not suitable for pumping.
  17. B

    Using a pump with a Combination/Fortic cylinder

    I get the impression that funds are not available for that!!
  18. B

    Using a pump with a Combination/Fortic cylinder

    Apart from anything else a pump has to be fitted in a certain way - not just 'in' the existing pipe work. You will not gain by fitting one and your existing system is not suitable for a pump. Don't do it!
  19. B

    ferroli 701 CH boiler

    When it's colder outside it will take longer to satisfy the room stat (as I'm sure you realise) but the boiler should continue to fire until the room stat is satisfied. The temp indicated on the boiler is controlled by a knob on the front of the boiler. If this is set at a position where...