Search results

  1. R

    Furthest radiators poor performance

    Flushed rads, and reconnected. Balanced system. so far so good. 'll leave it a week and I'll flush the whole thing out. When I drain the system should I leave the header tank alone, so as to create a flush of clean water through the system or tie it up ?
  2. R

    Furthest radiators poor performance

    Hmm, You know, I had a look around my system and the Einsteins that installed it didnt put in a drain-tap or whatever its called. In other words to drain it, Id have to disconnect a rad and figure out a way of catching all that water. Do you think I could just use the chemical and not drain...
  3. R

    Furthest radiators poor performance

    Can it be a balancing problem with all other rads except these two turned off?
  4. R

    Furthest radiators poor performance

    Hi, Ive turned off all radiators except for the two that are last in line from the boiler and pump. They are extremely slow to heat. The 2nd-last rad has hot inlet pipe, cold outlet pipe. The rad is hot at the top and cold at the bottom The last rad has a hot inlet pipe and a cold outlet...
  5. R

    Belmont O-ring substitute

    I had an idea, could I just wrap an elastic band around the spindle?
  6. R

    Belmont O-ring substitute

    Hi, I cant get my hands on a Belmont O-ring. any ideas on a substitute? Thanks! edit:typo
  7. R

    radiator leaking at inlet outlet valve

    its the last of the old radiators in the house believe it or not :) I don't have the cash at the moment to be buying a new rad, so plugging the leak for the meantime is my preference. I'll probably replace it before Christmas .though
  8. R

    radiator leaking at inlet outlet valve

    Hi Mo old radiator is leaking at both valves where the water comes in and out. Both valves are the screw type to either stop or allow the flow through the rad. They just have too much wear and tear. This rad is the furthest away from the boiler and its in a horrible position, and it old, so...
  9. R

    Hotpoint WD440 drum gets stuck

    Rocks1 Extreme gratitude and a veritable tsunami of good karma is heading your way right now. 10 mins to get the screws off. A bit of turning of the drum and there's the sock. Mangled and shredded. Im gonna get a whole load of brownie points from the missus for this. Thanks!
  10. R

    Hotpoint WD440 drum gets stuck

    Thanks for that Rocks1 Wont I have to remove the screws all the way around the hard plastic water proof casing to access the back? If you say no I'll be delighted. The thoughts of doing that is too much.
  11. R

    Whrilpool AWO/D 4507 noisy/banging drum!

    My banging around was caused by the drum spinning or just turning and then coming to an abrupt stop, and on and on.... If it was a coin woulndt it screech ?
  12. R

    Electrolux Cooker Hood Not Working

    Yep it was the 3 amp fuse in the plug
  13. R

    Whrilpool AWO/D 4507 noisy/banging drum!

    Mine is doing that. I think theres something stuck behind the drum. For the life of me I cant get it out. See if your drum has removable paddles. I could slide mine back and out.
  14. R

    Electrolux Cooker Hood Not Working

    Funnily enough mine sparked this morning and is now as dead as a dodo. I'll check the plug.
  15. R

    Electrolux glass hob circuit board replace

    Hi, My circuit board on my Electrolux hob has hit the dirt. Or so the 'engineer' with a phase tester has told me. He has also expertly told me that it would be as dear if not more so to replace that part. I dont really believe that and I was wondering has anyone ever replaced their own...
  16. R

    Hotpoint WD440 drum gets stuck

    Hi, I think there is something stuck behind the drum of my machine. It has thrown its belt. I can spin the drum a few times but it intermittently sticks. I can push it past the sticky point manually. I haven't heard steel-on-steel screeching so I dont think its the bearings. I definitely can...
Back