    Best Layout for Combi with Bells n’ Whistles

    Hello! Could any of you helpful people point me in the direction of a layout plan/diagram or similar for a combi boiler with the bells and whistles? I’m not trade and really looking forward to putting together a lovely setup (visually as well as correctly arranged in the eyes of a plumber)...
  2. L

    please help, roof a total disaster

    I agree; this membrane is to get normal tiles working at 12.5 deg.. not shallow pitched tiles working below 12.5deg.. my experience tho is it’ll probably pass with the fancy membrane and *close to* 12.5deg…
  3. L

    Any Issues With Fitting A Door Here?

    Lintel should have 150mm bearing each end if possible
  4. L

    please help, roof a total disaster

    here’s the data sheet
  5. L

    Brickwork to Flat Roof Verge Detail

    Hi Can anyone confirm my assertion that the detail shown here from NHBC is not actually achievable? How can one have the brickwork finish level with the top of the joists, so that the OSB deck and insulation can sail across the cavity, and deck sit on the brick wall, when firring strips need...
  6. L

    please help, roof a total disaster

    Hey, I didn’t read everything here thoroughly, and I’m not an experienced builder… ..but this might help.. there is a membrane called Klober Permo Extreme. It allows normal tiles to be used on very shallow pitched roofs. the plus side is you wouldn’t necessarily need to rebuild the pitch or...
  7. L

    Noob configuration idea for best of both worlds!

    thanks so the XXL is just a marketing thing.. the rapid it is then!
  8. L

    Noob configuration idea for best of both worlds!

    In that case, any idea why the Rapid is listed as about 13LPM at 35deg, and the Xtreme is marketed as “XXL” hot water profile “supports 2-3 bathrooms” yet the flow is only “slightly” better at 14.5deg?
  9. L

    Noob configuration idea for best of both worlds!

    Yes…but the flow from the combi is more than adequate for a shower.. no? Bare in mind nothing else would be connected. I think I’ll just go for the rapid, save the money and hassle with anything complicated and hope it’s fine for a shower and some simultaneous tap usage..
  10. L

    Noob configuration idea for best of both worlds!

    thanks both, I’m not concerned about noise but thanks for the info
  11. L

    Noob configuration idea for best of both worlds!

    I dont get this, why not feed the big things will the constant supply and the small things with a small cylinder?
  12. L

    Noob configuration idea for best of both worlds!

    Thanks for taking the time to advise all of that.. .. but I’m a little confused. I want to feed the bath and shower with the DHW side of the combi. I don’t get why, if I’m using a combi boiler, I wouldn’t take advantage of the heat on demand function for the shower, have a small cylinder...
  13. L

    Noob configuration idea for best of both worlds!

    I’m going to say 65psi and 18LPM, so that I get to hear your advice
  14. L

    Noob configuration idea for best of both worlds!

    im a bit confused Muggles, are you saying you’ve done the setup in my OP and it doesn’t matter that the mains going into the cylinder drops the pressure on the boiler like others have said, and also what do you mean you don’t connect the hot, what’s feeding the shower? If it’s the cylinder then...
  15. L

    Noob configuration idea for best of both worlds!

    Is this the setup I was originally talking about? did you do this for the reasons I mentioned…ie to allow shower and taps to be used simultaneously whilst using a combi to provide never ending water?
  16. L

    Noob configuration idea for best of both worlds!

    Thanks, I can’t really do that as boiler is in loft so I can’t get the gravity I need (noob here so apologies if wrong) Hmmm not sure, I know that I get 18 litres a minute on an outside tap as I’ve tested it with a bucket. As far as pressure I only know that it is “high”, as in for the...
  17. L

    Noob configuration idea for best of both worlds!

    So I should not bother with the cylinder then you reckon?
  18. L

    Noob configuration idea for best of both worlds!

    Interesting, no such thing as a free lunch comes to mind.. ..but wouldn’t my setup be good if I have a higher mains flow (18LPM) than the boiler can deal with, so it’s a way of removing that bottleneck so that I can demand higher hot water flows through the shower and tap at once?
  19. L

    Noob configuration idea for best of both worlds!

    ah that’s good to hear.. do you experience much effect on the shower when someone opens a tap? I don’t want that, it’s a busy household.. thanks