Search results

  1. D

    What's The Right Way To Finish Ceiling Edges?

    Why is there going to be a gap, boards pushed up tight to ceiling?
  2. D

    why was my concrete "rocky"?

    But don't tell the missus
  3. D

    why was my concrete "rocky"?

    Was that in anger or frustration?
  4. D

    why was my concrete "rocky"?

    I thought paving slabs were compressed during manufacture to give a denser and more durable product, the planters will be compacted by gravity and prodding
  5. D

    What UB or lintel over bifolds?

    Well a standard lintel will be designed with a 1/300 defection limit at design load which in your case means 10mm, usually a limit of 5mm for bifolds but depends on manufacturer. But as your lintel will not be loaded to its limit the deflection will be less, determine the load and ask the...
  6. D

    why was my concrete "rocky"?

    No, but at a guess I don't think it would take much load before failure due to the tension properties in concrete being about 10% of its compressive strength so for a 30N/mm2 concrete the tensile strength would be 3N/mm2 which is 150 times less the HY reinforcement
  7. D

    why was my concrete "rocky"?

    Watched a video on a concrete slab reinforced with glass fibre verses rebar and the rebar resisted 4x the load, also at failure the fibre slab was in 2 halves after loading whilst the rebar still held the concrete together in a fashion. I don't think we are ever going to see rebar replaced by...
  8. D

    why was my concrete "rocky"?

    Stranded fibre glass is there to prevent thermal cracking during drying, on small planters I would imagine the dimensions involved do not particularly lead to any drying stresses being set up so fibre not necessary
  9. D

    why was my concrete "rocky"?

    You are making some planters not building a reinforced multi storey car park (last time I performed a slump test) , forget plasticiser unless you are going to start laying bricks , just careful methodical tamping of a well mixed workable but not to sloppy batch as you fill the mould using a...
  10. D

    why was my concrete "rocky"?

    MOT was a Ministry of Transport spec for grading sub grade material (63mm or 40mm to dust) for road construction, nothing to do with concrete ballast. As long as what you are filling is 2.5 x larger than the largest stones used the compaction and finish of concrete will be OK, your 1 to 6 mix...
  11. D

    why was my concrete "rocky"?

    As long as you have vibrated/tamped your concrete in the planter to get rid of the air bubbles I think the end result will be OK
  12. D

    Giant Notch In Joist

    Interesting comment, on an evenly loaded floor half the load is carried at each end of the joist which is resisted by whatever the shear resistance of the joist is, the nearer a point load is to that end the greater the shear force. Since more than half the joist has been cut away the shear...
  13. D

    Stock market dealing

    :LOL: :LOL: :LOL: Unfortunately not. My return on shares over the past year has been about 20% which includes their gains and the dividends reinvested so at £5000 a week care fees for me and the wife we could last for about a year ( not taking into account govt pensions and company pension)...
  14. D

    Stock market dealing

    Yes its nice to make/save a few bob but at the end of the day there are a lot more important things in our lives. Hope things work out OK
  15. D

    Loft trussed roof ideas

    You could assume the rafters are normal rafters supported with a central beam and see what the calcs throw up re BM and deflection. Width ,depth and span required and dead load of tiles and if those short braces actually rest on a supporting wall below assume they act as a purlin this...
  16. D

    Water Pooling in Bath Plug Hole

    Or possibly the outlet pipework rises to an Invert Level the same height as your standing water level in the plug hole, unfortunately to remedy that would mean taking off the bath panel and checking the pipework
  17. D

    Loft trussed roof ideas

    Perhaps things may redistribute when you get the design snow load on the roof (75kg/m2 standard) which will then double or more the load that the current concrete tiles give (40 -80kg/m2) and the "lot of weight" becomes a lot lotter. I should imagine a SE will run a mile if asked to look at your...
  18. D

    Towel Radiator not working

    Put a towel under the rad and open the air bleed valve and let it issue water for a couple on minutes whilst the heating is on and see if any warmth comes through the pipe, I assume its a combi boiler so put the pressure up to 1.5 bar so it doesn't cut the boiler out.
  19. D

    Stock market dealing

    Well I don't need any bacteria just reading the above has made me off my head, heres to your speedy recovery