    baxi 105e diverter valve. What to do?

    You will never need to change a complete diverter valve on a Baxi 105e (unless leaking) Just remove the cartridge, clean and re-grease. If the problem persists then it's a blocked DHW heat exchanger. If they suggest you need a complete valve, then they are having your pants down.
  2. P

    UNSUAL WAY TO TEST A DHW CIRCULATING PUMP?

    Don't think I would of been using an fga 8 years ago on a CB24. It's not compulsory.
  3. P

    Joining Basin Waste to Shower Waste

    Should be ok, may need an anti vacuum trap on the basin to stop it sucking out the water in the shower trap.
  4. P

    Help with Alpha CB24 Boiler

    Take the diverter valve out, they aren't bad to do but may be a little awkward if it's your first.
  5. P

    Alpha 240E does not fire up

    Looks like you dont need advice
  6. P

    Boiler nightmare

    Looks like you've been took for a mug, and several times before. With an attitude like that may it continue :D
  7. P

    Please help me to identify this part

    Yes every time your BBQ gas bottle runs out you will need to call a Gassafe engineer to do it :lol:
  8. P

    Ballpark figure for new combi install (from back boiler)

    I will under cut Dan £8999 :wink:
  9. P

    Heat exchanger

    Badger76:- If it's a blocked heat exchanger due to sludge then best practice would be to flush the system then replace, boiler make and model is really irrelevent.
  10. P

    Y plan setup question

    Would not worry about fitting an air vent, dont need one. If its circulating through the coil ok, why generate more work.
  11. P

    NEW TIMER NEEDED - NO LAUGHING PLEASE!

    Danfoss 3020p might be a easy swap for you instead of wiring a new timeclock
  12. Untitled

    Untitled

  13. P

    Kitchen drains not airtight, new plumbing required?

    There is nothing wrong where the washing machine connection is going, its terminating exactly where it should.
  14. P

    Ravenheat water too hot.

    Does the gas pressure modulate down?
  15. P

    Ideal HE15 boiler advice

    It could be a faulty diverter/zone valve which will probably be in the airing cupboard.
  16. P

    Smell "Gas" but no gas leak

    Sounds like it may be an external leak. Call National Grid out again
  17. P

    Is this how to change Sacrificial Anode in my cylinder?

    So if the first reply to the post would have been "you should use a qualified plumber" instead of "you need a qualified plumber." Would you not have spat your dummy out?
  18. P

    To rip it out or start again?

    my apologies :oops: :)
  19. P

    To rip it out or start again?

    "Cross breeding" thought this only happened in Norfolk.