Search results

  1. L

    I-on40 RF Failure

    Hello, Alarm system reporting RF Failure after changing the battery. Tried full power reset still get the same error condition. All Wireless zones show not signal and alarm won't arm due to RF failure. Via HTTP, very slow opening and option selections very slow (2 mins). Was going to try and...
  2. L

    I-on40 RF Jamming

    Yep, 500 - 1600 mhz is for devices of low power and not requiring a license so find out what this is may be a little difficult. Whatever it is its breaking the Ofcom's Interface Requirement IR2030 in that's it's transmitting using high powered signal which is not permitted otherwise it would not...
  3. L

    I-on40 RF Jamming

    Hi there, i added the shock sensor back in this morning and re-tested the entire system and the RF warnings have now all cleared. I assume that the external signal (if that was the cause) would need to be stronger than the system the wireless devices are sending in order to mask mine or is it...
  4. L

    I-on40 RF Jamming

    Sorry should have mentioned, web connection shows all zone signals as strong, no fault, masking or tamper errors being shown when checked this morning. System log shows this:- 28/05/2020 23:15:25 SRN01 RF Warning (Radio SRN 01) 28/05/2020 23:15:25 Z23 RF Warning (GarageDoor)...
  5. L

    I-on40 RF Jamming

    Hello all, Problem when arming my I-on40 alarm in that several of the Wireless sensors reported RF jamming issues when the alarm was last set. From installation mode I tried to reset one of the shock sensors reporting rf jamming but this did not resolve the issue. In the end I removed the...
  6. L

    XCELRPT PIR Question.

    Hi, Placed system into walk-test mode for zone in question, waited 5 mins and then did a walk-test. Check keypad and sure enough zone shows status "A" for activated so it looks to be working correctly and that has you say LED is lit only when placed into test mode. Would have been nice if the...
  7. L

    XCELRPT PIR Question.

    So if i understand you correctly, PIR can talk one way only (PIR to Alarm) and therefore not set or unset signal from alarm to PIR is possible and after the default power-up period the PIR will no longer flash when movement crosses the PIR path. Further more, when a test is run from the alarm...
  8. L

    XCELRPT PIR Question.

    Hi Gibbies, Are you saying here that the PIR activity LED will not show activity when the system is unset as per a standard PIR and if so then the only way to test the PIR is functioning correctly is, 1) use the 30 min test period provided when the PIR is first powered up, 2) Arm the system and...
  9. L

    XCELRPT PIR Question.

    Here's the thing, when i place the system into walk test and I test the Radio PIR is does not register a trigger. If I place the system into Installed mode and I remove the tamper for the PIR and in doing so reset the PIR and then repeat the walk test it does trigger the Test. So during the...
  10. L

    XCELRPT PIR Question.

    Just fitted Wireless PIR which is paired up to I-on 40 no issues. After a period of 30 mins the PIR LED stops responding to movement. I seem to recall the PIR stays in self test mode for the first 30 mins of power-up but then goes into normal mode thereafter. Thing is I wasn't aware that normal...
  11. L

    Shed PIR Chime Question

    Why not make the zone for the shed PIR a double knock which means it won't go off until it picks up a number of triggers within the knock period.
  12. L

    I-on40 Install question

    Sorry, should have said the Bell Box is a Honeywell AG6 BELL BOX.
  13. L

    I-on40 Install question

    Hello all, I'm just about to change my TS900 panel with he I-on40 but got some questions. Firstly, access to the web portal how is this possable from the laptop (usb/Ethernet) and if ethernet does it have an RG45 connector? Secondly, can I get access to configure the panel without any special...
  14. L

    BellingIDW604 washing issues.

    Hi there, I've had this dishwasher for a few years now and to be honest it's always be crap at cleaning the plates but recently its got worse. There are no error codes and we always make sure the salt is full and we use a good brand detergent in it. We run through a cleaner every month and...
  15. L

    Menvier TS900 to Honeywell AG6

    Hi there, how much are you looking for, I'd like to get two if possible? Les.
  16. L

    Menvier TS900 to Honeywell AG6

    Sorry what do you mean, are the KP01 not compatible with the TS900 or is it that the kp01 won't work with the MKP1 keypads?
  17. L

    Menvier TS900 to Honeywell AG6

    I'm also purchasing a Cooper Key-KP01 which I want to use along side the MKP1 keypads. I notice the connections are different however with the TS900 having A,B,C,D & E network connectors and the KP01 having 0v,12v A B RAS485. I know the A on KP1 is 12v and the B is 0v what what about the data...
  18. L

    Menvier TS900 to Honeywell AG6

    Yes I was thinking about having a seperate 12v 3amp feed from a PSU given that I also have two internal sounders feeding of the 1amp supply.
  19. L

    Menvier TS900 to Honeywell AG6

    cheers mate, that's got to be one of the quickest replies I've ever had back from any forum:):)
Back