    Hi DX90 I had to fit a wylex plastic NH series consumer unit to a TT system 3 weeks ago, because there was no isolating switch, I tried to purchase a 100ma Time delayed RCD to swop out the main double pole isolator, I could not find one that was compatable with the NH enclosure, so I rang...
  2. R

    100mA RCD tripping problem

    I had the same problem with a wylex board on a TT system 2 weeks ago, Wylex advised that the 100ma TD RCD had to be fitted in a separate enclosure and could not be exchanged for the main switch as shown in your photos.
  3. R

    TT system,

    Thanks Aardvark, I will look into that, but that will still require it's own earth rod w'ont it.
  4. R

    TT system,

    The main system is TT, the customer has requested a new consumer unit, currently the garage is fed by a 2.5mm T & E which I beleive is contary to BS7671, I intend to fit 100ma TD RCD main isolator. followed by a split load board with 30ma RCD protection, How ever the garage is detached and...
  5. R

    TT system,

    can someone please just clarify the earthing requiremnts for a stand alone garage when the main house is on a TT system. I believe I have read somewhere that it requires it's own earth stake? Thanks Guys
  6. R

    MFI fridge/freezer seems warm help

    Go into your local MFI and ask them to print the users manual which should be on the storelink site, or photo copy a manual from one they have on display.
  7. R

    new cooker can't be installed

    The diamensions quoted to you are from BS6172 2004 however these are normally only applicable to gas appliances because of a naked flame. The diamension for the wall unit to worktop is 460mm.
  8. R

    reasons for bridging earths?

    Could this possibly be a DIY Faraday cage