    Worcester 28i rsf combi not working!

    Have you got any means of confirming this ie multimeter neon screwdriver etc
  2. rochdalegas

    Worcester Condensate Pump Issues?

    The condensate pipe going into the condensate is unlikely to be frozen. Has it got a clear hosepipe type pipe running off could be worth bowing down that is likely any frozen part. It may have been blocked or have a jamming float valve. Tbh as its working would just leave to bg to sort as and...
  3. rochdalegas

    Worcester Condensate Pump Issues?

    More than likely that wherever the condenaste pump is pumping to is frozen en route.
  4. rochdalegas

    Worcester 28i rsf combi not working!

    All fuses including the pcb fuse?
  5. rochdalegas

    Ravenheat completely cutting out CH, tapping PCB housing works

    It can be expensive lesson to just start throwing parts at it especially expensive pcbs. For whats its worth the thermistors are a quite prone to playing up and are lot cheaper to change sounds lile a overheating issue to me. Again it would be better to carry out some basic checks first before...
  6. rochdalegas

    Ravenheat completely cutting out CH, tapping PCB housing works

    Getting someone in who knows what they are doing would be a better idea.
  7. rochdalegas

    Worcester Bosch compact - any drawbacks over classic?

    Would never personally go for a compact where a regular sized boiler would fit. The former usually have had comprises to save space The latter are generally better laid out and easier to work on. Boilers like anything dont like to be sat around for months on end the fans in particularly on...
  8. rochdalegas

    No hot water

    Chances are its something done today to much of a coincidence. Biasi combi or system boiler? Did he just change stat at wall or renew wiring etc in boiler. Check the obvious first stat to hw left down for example.
  9. rochdalegas

    Boiler won't repressurise

    That is fully open (on)
  10. rochdalegas

    Boiler won't repressurise

    Double check you have turned both islation taps fully off exactly 90 degrees across for the slots then keep bleeding I radiator even after water comes out with a bowl catching the water untill its around 1.2 bar.
  11. rochdalegas

    Banging when central heating turns on and radiators not getting warm

    They are "self bleeding" pumps so no bleed screw I think they suggest running it on higest speed for a couple of days.
  12. rochdalegas

    Central heating problems

    Firstly ive never held my g3 cert so im unqualified to advise on position of expansion etc im sure there are more experienced who would be more knowledgable. You should also get someone in to to that side with appropiate quals. As for the heating side. Its worth checking if your boiler has an...
  13. rochdalegas

    Banging when central heating turns on and radiators not getting warm

    Sounds like the pump may be sticking. Have you had any problems with sludge in system
  14. rochdalegas

    Leaky Radiator

    Re remove tail you need around a dozen wraps of ptfe going clockwise. A smear of plumbers mate wont to it any harm also check the leak isnt from the valve face as they have a habit of tricking you into where you think the leak is
  15. rochdalegas

    Greenstar Highflow 440. Loss of pressure

    Very straightforward in these.one nut and one screw if i remember correctly.
  16. rochdalegas

    Greenstar Highflow 440. Loss of pressure

    If you had water at the shraeder valve i would expect the expansion vessel would need changing sooner rather than later.
  17. rochdalegas

    Adverse effects of too much X-100

    It will be perfectly ok better to have too much opposed to too little.
  18. rochdalegas

    Own brand Vs big brand mixer

    What muggles said. Big fan of vado myself.
  19. rochdalegas

    Going forward with updating old heating / hot water system in bungalow

    I know if it was me id be fitting a combi with a mixer shower asap it would fit your needs perfectly. If you are intent on keeping the wau Whatever you do get it serviced regulary by someone who knows what they are doing as they have the potential to become very dangerous given its age I would...
  20. rochdalegas

    Central heating problems

    I think a good starting point would be to fit a gate valve on the hot water side so that can be balanced down along with the radiators. Above to motorized valve on the hw flow