  1. T

    Drilling 12mm holes in UPVC Conservatory side panel and sill for BT Full Fibre install

    Have you got a full picture of the conservatory and maybe we can come up with a different idea?
  2. T

    Average cost to move GAS BOX

    Decide where you want it and use cadents diversion service to get a price. They moved our meter about 6m from inside our old garage to outside our newly built porch, they had to fit us a brand new line too as we were twinned with our neighbours. That lot cost us £491, I dug the new trench on...
  3. T

    How to cut metal sheet part from electrical lamp base?

    You can drill it as you originally planned but you need a centre punch to mark the centre first to stop the drill wandering.
  4. T

    WC into understairs pantry - nightmare

    We've told you what needs to be done and you just keep coming back trying to get a pro to say that while it's a lash up it'll be ok aslong as it's not leaking so you can justify leaving it as is. All the advice you need is in this thread.
  5. T

    How to remove protruding metal around hole after drilling

    An 8mm hss drill bit from toolstation is £3.58. If you want to use a file then I'd use a round needle file personally but I'd imagine one will cost more than the drill bit.
  6. T

    Hob connection check

    Think you need to take a photo of what's actually behind the fcu, if he's just used Wago's to join the 2 cables and none of the screw terminals on the fcu faceplate then the cable won't be fused by the fcu.
  7. T

    WC into understairs pantry - nightmare

    The flexi is a problem as the ridges in it catch the more solid stuff that goes down the toilet and slowly builds up till it causes a blockage. The 90 degree is completely smooth internally so the weight of water forces everything along it. And that's without the rat consideration. Im only a...
  8. T

    WC into understairs pantry - nightmare

    The pictures look like you can remove more of the wall to remove the need for the offset connector. Get yourself a 90 degree pan connector, fit it to the toilet with the outlet horizontal. That will then attach to the white 110mm pipe you've already got, remove whatever wall is stopping it...
  9. T

    Ideal Logic Combi 30 boiler

    You shouldn't really have the front cover off the boiler. If you've not used the taps thtlat isolate the boiler in awhile the it's likely they won't work and will still allow water to pass. Your issue is likely to be either the expansion vessel or heat exchange vessel, both common issues on...
  10. T

    DPF removal

    It is an mot failure to do anything but replace it with a working unit, you'll need the car remapped to delete it which is easy enough for most cars nowadays. You'll need to either force a hole through it from end to end the diameter of the exhaust pipework or cut it open and remove the...
  11. T

    WC into understairs pantry - nightmare

    Sorry but you've pretty much made it worse by including a flexi. Judging by the last picture you've way more fall on that pipe than you need, if you had less fall you'd be able to get all the pipework inline alot better and lose that offset joint aswell.
  12. T

    Relocating soil pipe and inspection chamber

    It's going to be seriously expensive especially given your not going to actually gain anything. There's no reason for there to be any issue with your sewer but if your after piece of mind ask your neighbour if either they have a cctv survey showing your sewer from when there sewer was moved or...
  13. T

    Do these compression need changing?

    Ok hopefully you can make sense of this, Remove the section of pipe circled in yellow and put to one side. Remove the blue filter, and both it's plastic fittings. Remove the copper loop to the right of the filter all the way to that Iso valve next to the blue line I've drawn. Get a 15mm...
  14. T

    Do these compression need changing?

    Is the direction of flow through the filter from left to right or the opposite way?
  15. T

    Do these compression need changing?

    Could you take a photo of the pipework to the left of that picture, the blue bit is basically installed in a loop so it's possible to tidy up the pipework further
  16. T

    Makita Radio

    No buttons stuck in?
  17. T

    Do these compression need changing?

    If there not leaking then no, I'd probably clean them up with a bit of emery cloth as then you'd know any future build up is a leak but it'll do no harm leaving them.
  18. T

    Sink Waste Query

    https://www.toolstation.com/washing-machine-plastic-valve-cap/p30766?store=null&utm_source=googleshopping&utm_medium=feed&utm_campaign=googleshoppingfeed&gad_source=1&gclid=Cj0KCQiAj9m7BhD1ARIsANsIIvAzPAPi9U38xkMmDm7HDg9beFhf4OvrKEXKQ2EmSq8aH-5FoAdQGbkaAgrREALw_wcB That would probably be my...
  19. T

    Sink Waste Query

    https://www.screwfix.com/p/mcalpine-s23u-multifit-blanking-plug-white-32mm/73053 I'm going to hazard a guess you want one of the above
  20. T

    Downstairs toilet options (looking for advice)

    You could get a socket bend which would allow the pipe to follow the line I've marked in orange, you could at least then box that bit in and have a chance of making it look reasonable once you repair the stair.