    ariston dishwasher loud pop

    No sorry, better off posting in the appliance forum to be honest. Hope you get sorted
  2. G

    Vibration in central heating system

    A lot of engineers i know when commissioning just close the bypass fully then open it a crack to allow just enough water through, obviously not the correct way. Try turning your pump down to speed 2 and follow the commissioning steps in the PDF then youre basically doing with the bypass what...
  3. G

    Runnning water from Worcester Bosch 30Cdi condensate pipe

    The dribble when the boilers not on could be due to lack of fall on the pipe work, whatever the problem its the installer that should be returning and probably wont because its not terminated correctly
  4. G

    Air locks

    Im not sure if he means out the hot water or heating though
  5. G

    Worcester Green star 18-25kw pump connected on return pipes?

    Depends on the position of your open vent etc, On the flow pipe coming from the boiler the order should be 1) Open vent 2) Cold feed 3) Pump So by putting the pump on the return by the boiler thats how they achieved that sequence, the most important thing is get the vent right I...
  6. G

    Air locks

    Sorry, i dont quite understand what youre saying, what system do you have?
  7. G

    No hot water following draining of combi boiler

    It is the most logical out come to me from what youve said about the work done there. Ive known established engineers get it wrong who should know better so dont rule it out. Have a look and get back...
  8. G

    Worcester Green star 18-25kw pump connected on return pipes?

    Quite normal practice to put a pump on the return due to the lower running temperature (most combis do this also) As long as you havent changed any controls or much of the system pipe work you should be ok Get your oil pump pressure checked and commissioned by an engineer though, ive had a...
  9. G

    No hot water following draining of combi boiler

    Sounds possibly like you might have the hot and colds wrong going to the boiler from what you have said, follow the main from where it comes into your flat and triple check it goes onto the inlet side of your boiler
  10. G

    Runnning water from Worcester Bosch 30Cdi condensate pipe

    Yeah, theres supposed to be condensate running from that pipe its the nature of your he boiler However it shouldnt be running onto slabs, it should be run to a drain ideally, bit naughty that!! Get him back because its not fitted to manufacturers instructions
  11. G

    Storing copper fittings

    I got those for my screws/plugs and another for clips didnt think they would hold enough fittings so might try the bigger fat max, cheers
  12. G

    Storing copper fittings

    What do you guys use?? Ive never got past 3, 4 gal F and E tanks in the van but want something a touch more professional Not sure if this is the right place to ask but i am!
  13. G

    Mixer shower doesn't get hot

    some shower pumps need auto air bleeds coming from the pump to the shower this is normally only a problem if the pump isnt starting properly though but might be worth a try, have a gander in the instructions
  14. G

    Worcester 24CDi (old) replacement of Pressure Relief Valve

    http://www.worcester-bosch.co.uk/installer/literature/discontinued-boiler-literature/discontinued-gas-boiler-literature/24cdi-bf-discontinued-march-2005-literature Page 20 of the installation and service pdf
  15. G

    Flux

    WHAT A ****ING MESS
  16. G

    pilot light is not alight and thermocouple is changed

    You could bridge it out (very) temporary to see if its the stat faulty would probably be the easiest. Otherwise, could be tip not in the pilot light, nut not tightened on the gas valve from the thermocouple or the gas valve itself, rarely the gas valve though. Please dont play with gas if...