Search results

  1. Gasop

    How to shorten a copper pipe?

    Should be no problem cutting 2-3mm off the pipe with a decent junior saw and blade. Forget the file. Goodness knows how much crap and filings dropped down the pipe into the system.
  2. Gasop

    Another stop cock?

    If it is the hot tap dripping then just turn off the cold supply to the boiler. You will find that valve under the boiler.
  3. Gasop

    Trouble re-igniting the boiler

    Check the system pressure has not dropped. Look for at least 1bar on the pressure gauge.
  4. Gasop

    Internal Gas Pipe damage

    Yes it is possible to have a nail in a gas pipe with no problems or gas smell for nine years. Turn off your gas at the emergency valve at the meter and call in a registered gas fitter to investigate and put right if required. Don't let the builder do any work on it at all unless he can...
  5. Gasop

    cannot get to tap washer - any help?

    I would say that the screw is under the disc on top where the H is. Use some rag or tissue under a pair of grips or pliers and unscrew it.
  6. Gasop

    going crazy with leaks at junctions and stoppers.....

    I right click on the little squares and open in a new tab.
  7. Gasop

    going crazy with leaks at junctions and stoppers.....

    Looks like a Philmac or similar make of end cap. Get rid of all that PTFE tape and reassemble. That stuff has no business on that type of compression fitting. Make sure that the gripper and O rings go back in the correct order. Also make sure you have the correct size/type of fitting...
  8. Gasop

    ceilings

    :cry: No leg over last night I take it. :wink:
  9. Gasop

    Pub beer prices in uk.

    Exactly. I wrote it that way as the majority on here would not likely to understand 1/3. Translated to more modern coinage, 6.25p
  10. Gasop

    Pub beer prices in uk.

    Watneys 1964 1s 3p a pint. :twisted: :wink:
  11. Gasop

    fitting new syncro switch on honeywell 2 port valve

    :( :( TWO screws :?: I only got one this month (or was it this year??) ahh, well, :twisted:
  12. Gasop

    Hot Water Problem

    The first thing to check would be the shower head. Make sure the flow has not been reduced too much due to lime scale. Remove the head and turn on the shower, does the water heat up properly now?
  13. Gasop

    Thermostat has to be 20 +

    Either your room stat is faulty or the temperature in the hall is higher than the temp you are trying to set to. Put another thermometer close to the room stat for a few hours to check against.
  14. Gasop

    Mains pipe in wall

    :lol: :lol:
  15. Gasop

    How many RGI's here Do their own electical Work.

    I suspect Dr. Drivel has appeared under a new alias :wink: :wink:
  16. Gasop

    new boiler commission

    Is that all? I was under the impression it was in excess of £300 :)
  17. Gasop

    new boiler commission

    You say you are competent to install your own boiler. There is nothing to stop you doing the install yourself and making the notification to building control. There is no requirement to notify through Gassafe (or any other organisation) Building control will inspect the installation...
  18. Gasop

    can you see what wrong with this system? (boiler)

    :oops: :oops: You are right. Don,t know what's wrong with my eyesight tonight. Thought flexes were opposite to each other. :(
  19. Gasop

    can you see what wrong with this system? (boiler)

    Bottom zone valve on backwards.
  20. Gasop

    Relocate gas connection pipe height?

    Mmmmmmmmmmmmmm..... :twisted:
Back