  1. B

    combi pressure rising!!!

    check faq`s for represurising expansion vessel also make sure the cold main tap isnt passing and constantly filling the system. if the pressure rise is when heating is on -exp ves still rising when boiler off-tap passing
  2. B

    FERROLI BOILER PROBLEM - OWNERS CONTACT ME HERE

    so you need a t`mistor on an optima and you want the world to contact you so you can play silly buggers with ferroli? who diagnosed a t`mistor and the boiler stat? how much would you like ferroli to charge to come out?
  3. Untitled

    Untitled

  4. B

    If you were not a plumber what would you do ?

    gas safe inspector they do **** all anyway
  5. B

    HELP- Boiler is busted

    i would phone someone else :!: did you pay the guy?
  6. B

    Gas grill stopped worked - HELP PLEASE

    buy a toaster :mrgreen:
  7. B

    Vokera Excell 80 sp quick question

    the fan will run on low speed to supply oxygen to the pilot and disipate the heat
  8. B

    Vokera COmpact Combi Hot water

    lost me there? what is the pressure when the boiler is off/cold? should be 1 -1.5 how much does it rise when heating running ? should not go above 2-2.5 had the pressure dropped to zero when you had the red light? low pressure/lockout will give the red light the sensor fault i was on...
  9. B

    Vokera COmpact Combi Hot water

    solid red light is usually primary ntc sensor but can be board
  10. B

    solvent weld waste converted to push fit

    the push fit stuff is a different size so yes you would have to use a compression
  11. B

    Looking for Local Gas Engineer Glasgow area

    first advise is dont use the fire at all.has the hw deteriorated with the recent cold snap?try running your taps a bit slower.im available on monday.also get a carbon monoxide alarm :idea:
  12. B

    Ferroli Modena 102

    fill up and check if it rises to above 3bar.expansion vessel on the back of the 102 (off the wall shot).as said check the prv (manifold type) can be a pain to change if not much room below the boiler
  13. B

    Help with boiler please

    there is a bit of movement,just check it not leaking upwars from around the pipe.best bet is to take the two nuts of the filter and use a little ptfe on the threads.you did drain it throught the drain tap and not the prv?
  14. B

    2 weeks now

    you can have my password for a one off fixed price of £86 :mrgreen:
  15. B

    Help with boiler please

    the aqua filter on them leak like ****.touch one bit and the other will leak too.brass nuts onto plastic are rubbish,get some ptfe tape onto it.also check you havent moved the pipe that goes into the divertor (follow the aqua pipe to the left) its held in by a circlip and tightening the aqua...
  16. B

    water gets hot then goes cold, help please.

    Service kit not always fitted on service.trust mr get the kit fitted and get the motor checked/changed
  17. B

    water gets hot then goes cold, help please.

    Service kit and service req most likely.if your capable take the case off and check the divertor motor is moving.just a circlip holding it in place.sometimes it leaks at the pin and takes out the motor
  18. B

    water gets hot then goes cold, help please.

    Run the hw and hold the central heating pipe or check the first radiator and see if it gets hot
  19. B

    In a big mess, dont know what to do please help! :(

    If there is a leak at a rad valve they fitted they should fix it.get them to check other valves and any pipework they altered at the boiler.what does the pressure rise to when the heating is on?what are you filling it to?nobody on here can fix it for you,deal with the installers