    Pressurised Cylinder & Mains Pressure.

    That should've fine mate. I take it your a normal house and not 3stories? What is your incoming main size? Material? If it's mdpe (plastic) you would be better changing the stop tap to a 22mm outlet and supplying the cylinder with a 22mm feed. 15mm is acceptable but 22 is better
  2. L

    Pressurised Cylinder & Mains Pressure.

    Pressure is important with this type of system. More so tho is flow rate. Do you have a standing pressure if 2.5bar or working? How long does it take to fill a 5 litre jug?
  3. L

    External soil pipe leaking at seal

    Persoal choice. I just don't like em
  4. L

    Can a soil pipe be vented like this?

    Rich you may have one of mine lol
  5. L

    Can a soil pipe be vented like this?

    They will act as a trap and stop syphonage mate.
  6. L

    External soil pipe leaking at seal

    Its rubber mate so as long as the paint is flexible, i can see why not.
  7. L

    Vertical radiators - B&Q or Myson ???

    PURMO's are good too. Ive use B&Q's verticle panel rads at home and they have been fine.
  8. L

    Can a soil pipe be vented like this?

    cap it off mate, it will be fine. If your worried, get a 3"x2" adapter and fit a 2" AAV at the open end
  9. L

    shower pump pipework

    i know mate, I prefer copper but to be honest, nowa days you have to fit plastic to be competative especially on new build. I can 1st fix 3 x 3 bed houses on my own in a day with plastic. Copper and im down to 1. Most plastic companies give A 25YEAR garauntee.
  10. L

    Combi vs Open Vent for 3 Bed family home

    the 222 is the dogs danglies and will fit in most airing cupboards
  11. L

    Can a soil pipe be vented like this?

    How long is that 3" run? id cap it off tbh. cant see you having any problems with it.
  12. L

    Solid fuel central heating

    Hold the phone, so sorry it was late and I just seen the gas Ch and open vent. Didn't realise he was swapping for a stove. Worked a fair bit on steam in cholomendy BTW. ignore me. On another note, is the stove new? Is it piped up correctly ? Is the pump pumping the correct way? Does it have a...
  13. L

    BUILDING AN EXTENSION

    Doesn't say that on the portal lol
  14. L

    Solid fuel central heating

    Personally I would bin the header tank and fit a vessel,gauge, blow off and loop as suggested. What number is the pump on? More than likely sucking in air as said. Also is the pump running?
  15. L

    External soil pipe leaking at seal

    Here you go mate. You want a ec002 mechanical one will be easier to fit for you. The pushfit is intended for cast but the mechanical ones fit just the same. The fernco one will also do the job and will be a stock item however they don't look the best. Your choice really...
  16. L

    External soil pipe leaking at seal

    Just thought on, you could also use a propper 4" cast coupling. Can't remember who make them but drain Center could order you one. Has two cast half's and a rubber band seal. This bolts over the seal. Would be slot easier for you that way and will look fine painted. See I I can find you a link
  17. L

    BUILDING AN EXTENSION

    Whats this 45deg rule? I demand to know NOW!!!!! lo :wink:
  18. L

    External soil pipe leaking at seal

    More than likey cast mate, Id cut it out from the fit a cast-plastic adapter then re-fit it in plastic. Pretty simple tbh. The easiest option is a band coupling but as said bud they dont look too nice.
  19. L

    BOILER IN CELLAR ---TEMP & PRESSURE RELIEF DISCHARGE MAN

    IIRC the wires are connected inline with the boiler SL. Ill have a look at the docs now for you.