Search results

  1. A

    Texecom 24 - PIRs Preventing Arming

    Sorry to jump the thread. I will start a different one with my questions. Thanks.
  2. A

    Texecom 24 - PIRs Preventing Arming

    I forgot to mention that i have 8XE onboard zone expander which is working
  3. A

    Texecom 24 - PIRs Preventing Arming

    Hi guys, can i just jump onto this thread as i have just wired my first TExecom system. I have two RKPs, 8xp-w, 9 wired motions, 1 wired contact, 3 wireless motions and 1 wireless contact. 1 beam detector and 2 smoke alarms. I have a few problems. Using wintex to program everything. I am happy...
  4. A

    PIR wiring method for elite 24

    That's fine then. My understanding is correct. I am using the built in resistors. Tamper 2k2 and alarm 4k7. Cheers. Just re-read your reply, is EOL another name for tamper then?
  5. A

    PIR wiring method for elite 24

    Hi, I just wanted clarity on something please. The PIR wiring method I used following the manual is: I connected a wire from zone 2 (on control panel) to terminal 1 (tamper on the PIR) and the other zone 2 wire from control panel to terminal 4 (which is alarm on the PIR). Is that correct...
  6. A

    Texecom speech and text dialler wiring to elite 24

    Thank you for all your help. I may need more when I get stuck.
  7. A

    Texecom speech and text dialler wiring to elite 24

    Picture may be poor quality but wiring is 12v(red), 0v (Black), Com (Blue) and N/C (Yellow). I have put the blue and yellow into Zone 7. Is this correct? For future reference, if I were to use the latch terminal. Is the manual saying to connect the Red wire to the latch terminal, i.e giving the...
  8. A

    Texecom speech and text dialler wiring to elite 24

    From the Exodus smoke detector manual: The Exodus 4W Series can be configured as either auto reset or latching depending on how the Latch Input is wired. Latch Input: No Connection or 0V: Auto reset (detector automatically resets after the smoke or heat has gone). +12V: Latching (after a...
  9. A

    Texecom speech and text dialler wiring to elite 24

    Thanks SecureIam, very quick response. So just for summary: 1) I take it the 3 first three trigger inputs are pre-configured but can be changed if required 2) One wire from trigger input 1 to digicom output 1 is enough as long as digicom output 1 is configured for active on fire? Now, I have...
  10. A

    Texecom speech and text dialler wiring to elite 24

    Hi, I hope you can help. This is probably a very basic question but need some understanding. Please tell me if I have wired correctly: Speech dialler Elite 24 control panel TAMP terminals Aux/Fault Connections Trigger 1 (Fire)...
Back