  1. Echo the husky

    Device attached to ducting?

    Isn't that where it should be?
  2. Echo the husky

    Device attached to ducting?

    Yes, as long as the duct vents properly to the outside. The duct should also be insulated to stop condensation on the inside, this often then runs down the motor wires and damages the timer circuit board for the fan. These are cheap fan kits, often with poor performance. The bit in the ceiling...
  3. Echo the husky

    Device attached to ducting?

    That's the fan!
  4. Echo the husky

    Identify shower cable

    That would suggest 4.0mm².
  5. Echo the husky

    One gang socket with USB

    12V is for the rear terminals T1&T2, 5V for the USB input.
  6. Echo the husky

    One gang socket with USB

    Their wiring is different, they don't use the heatlink for one, the Nest controller does it all, hence the 10 terminals rather than the 2 in the UK model. I guess it would be difficult to get power to the unit without extra wiring.
  7. Echo the husky

    Grundfos pump still not working

    I did wonder, a neon screwdriver wont detect a missing neutral.
  8. Echo the husky

    Advice needed replacing an old Powermax 155

    Not using electric when a gas supply is available would be a start! Switching to electric will be incredibly expensive to run. We look after a few houses with such an arrangement, requiring large stores of hot water for the heating, and hot water, heated with 18KW worth of immersion heaters...
  9. Echo the husky

    Grundfos pump still not working

    Is there power at the pumps terminals?
  10. Echo the husky

    Vaillant TURBOmax Plus - filling?

    The refill time on mine takes a while too, though not that long, but I have high water pressure. If it has suddenly lost all that water there may be a leak, or the expansion vessel and pressure relief valve may require servicing/replacement. Also check the pressure relief pipe that goes outside...
  11. Echo the husky

    Vaillant TURBOmax Plus - filling?

    The boiler comes with a key that fits these 2 valves. Turn both 90° anticlockwise to fill boiler, then turn both back. The slot indicates the valve position, front to back closed, left to right open. They are often stiff if they haven't been operated in a long time. Some radiator bleed keys will...
  12. Echo the husky

    Things That Go Bang in the Night!

    ^ Beat me to it!
  13. Echo the husky

    One gang socket with USB

    A skilled electrician might be able to hide the cables, I assume you have a combi boiler and no hot water cylinder?
  14. Echo the husky

    One gang socket with USB

    The heatlink (what the nest controller talks to) has 2 terminals T1 and T2, these connect to the 2 terminals on the wall mounting plate of the nest controller to provide power without the usb.
  15. Echo the husky

    reels of 100 yards 4491X 7/044 red cable

    Seen plenty of imperial cable with green slime. Sadly it's quite common around here.
  16. Echo the husky

    How to connect a 2-gang switch!

    :rolleyes:
  17. Echo the husky

    hook lock alignment on Irwin Hilmor GLM pipe bender

    Return them, they are not fit for purpose.
  18. Echo the husky

    Underfloor heating controls - a conundrum

    Wow what an absolute mess. Not to mention using the bare earth wire as a switched live. Terrible. I would recommend contacting someone competent to work on heating wiring to install it properly, and safely.
  19. Echo the husky

    Replacement Thermostat

    The capacitor can age with use, where its capacitance value drops. A very common problem in all sorts of things that use film capacitors in mains positions.