  1. Echo the husky

    Compressor central heating - breaking every week or so

    I've wired several and repaired several others.
  2. Echo the husky

    Compressor central heating - breaking every week or so

    I know I don't ever want to see a Worcester one again. I quite like the Daikin ones though.
  3. Echo the husky

    worcester heatslave 12/14 intermittent lockout

    The silver capacitor in the photo appears to have inflated.
  4. Echo the husky

    Light with multiple bulbs burnt wiring help

    I love that ceiling!
  5. Echo the husky

    Honeywell DT92E

    That's posh! I'll have to look into that. I still use MS Paint...
  6. Echo the husky

    Does anyone know anything about sunvic actuators

    BG like using plugs on the valves, they often make a right mess of wiring them too.
  7. Echo the husky

    Junction type box

    That circuit in the photos is just a timer for the stairway lights, I assume the light switches are the retractive type? What sort of fittings are the emergency lights? Very old flats may have just a single unmetered fuse coming off the incoming supply for the communal lights. Where did this...
  8. Echo the husky

    Danfoss tp5000si (non wireless) not communicating with rx1

    Switch off mains supply to the central heating, unclip stat from backplate. Connect the wires that are in terminals 2&3 (com&on) and join them together in the same terminal or a connector block. Switch the mains supply back on and the heating should come on now. If it does the thermostat is...
  9. Echo the husky

    CT / PG difference

    I did :)
  10. Echo the husky

    CT / PG difference

    WHY IS IT NOT LEVEL AND ALIGNED?!
  11. Echo the husky

    Smart Meters 'forced' on people?

    I'll have to look.
  12. Echo the husky

    15mm fitting won't fit (what is table Z)

    Think of the money you will now save not having to buy any more couplers!
  13. Echo the husky

    Smart Meters 'forced' on people?

    It basically said you allow the supplier to do whatever they want including changing the tariff. If I get the time I will find the information and post it here. The conditions were pages long and information was hidden behind links and I had to go all over the place to get all the information...
  14. Echo the husky

    Siemens dva3 clicking

    The top picture is the valve body, the slotted shaft should turn back and forth easily, its travel is only a few degrees though. The plastic rack teeth look very worn. If the body shaft moves freely you can just replace the valve actuator head, if not, replace the whole lot.
  15. Echo the husky

    Smart Meters 'forced' on people?

    It's the variable tariff adjusted around the customers usage that is one concern for me. The terms from my supplier said you agree to he price per unit being changed without warning at different times of the day depending on usage.
  16. Echo the husky

    Ideal Logic+ Reversed pipe connections

    There is no + and -. The pumps live should be connected to the cylinder stats call for heat connection as it directly switches the pump and boiler on. See Y plan diagram. The valve may hum gently as when the motor has reached the correct position, as it is still powered, but stalled. Your fault...
  17. Echo the husky

    UFH manifold TMV control

    Photos, make and model of UFH and valve etc.?
  18. Echo the husky

    Any Saniflo experts on here?

    450V is correct, fit it it will be fine as long as the old one was also 4μF. Most motor caps will be 450V rated.
  19. Echo the husky

    Smart Meters 'forced' on people?

    Did you read your smart meter terms and conditions or did you just automatically agree to them when you were asked if you wanted a smart meter?