  1. tininho

    Ideal Isar m30100 cuts out error LF when hot tap turned off

    By the way... is it noisy when in operation????......
  2. tininho

    Ideal Isar m30100 cuts out error LF when hot tap turned off

    Hi, The LF fault is an ignition fault, or flame failure.... My First port of call would be a fan or flue fault.... When running in H/W mode, the fan works at a higher rate than in CH mode, so that the gas/air ratio is higher, thus alowing maximum heat output.... If the fan is sluggish it...
  3. tininho

    No Hot Water but Central Heating OK

    hi, allowing the system to "boil up" is a very handy trick.... particularly with back boiler units, however if it doesn't work on the first attempt I would tend to assume this isn't correcting the fault.... from what you've said it is quite definately a circulation fault and is almost certain...
  4. tininho

    No Hot Water but Central Heating OK

    hi, could be a few things.... given the burst pipe issue it seems most likely to be a bugger of an air lock, or perhaps the cold feed may be choked.... What is the water content of the system like??? clear? black and sludgy??? If it is choked, it is quite possible that when the system was...
  5. tininho

    Vokera Excell boiler

    Yea I agree.... sounds like the pump is struggling Martin
  6. tininho

    Boiler keeps stopping & starting every 30 seconds or so

    Indeed... However, I have in the past come across faulty motorised valves, where the syncron is beginning to sieze up to the extent that the end-switch makes and then drops out repeatedly..... Just a thought
  7. tininho

    Boiler keeps stopping & starting every 30 seconds or so

    it would run for longer than 30 secs if the pump was at fault..... would be pretty noisy too..... suppose the venturi could be partially blocked, but still reckon the mid-pos valve (or zone valve) is most likely.... Martin
  8. tininho

    Boiler keeps stopping & starting every 30 seconds or so

    Hi, Depends really... Is the red lock-out indicator illuminating during the process??? Sounds like either your mid-position actuator is jamming and not motoring fully over...... or an air lock, possibly a choked cold feed if it is on an open vented system (though this is unlikely....)...
  9. tininho

    central heating

    Depends on the system you have.... do you know if it is fully pumped????
  10. tininho

    central heating

    Why do you need a manual valve???? this can all be done by setting the programer....