  1. Gasop

    Hob condemned tonight

    Takes me longer than that to find mine the state the van is in :lol: :lol:
  2. Gasop

    Fitting Surrey flange

    Not really any need to drain down at all when fitting a Surrey flange. Just make sure cold feed turned off properly and open the lowest hot tap to empty pipework. Have an old towel or rag handy to soak up small ammount of water displaced when fitting.
  3. Gasop

    Old back burner Gas Boiler Fault

    Check that the pump is running when the room thermostat (if fitted) and programmer is calling for heat.
  4. Gasop

    Problem with vertical tube radiator - help required!

    Are the flow and return connections both at the bottom? If not then what are the piping arrangements?
  5. Gasop

    forum running slow

    No problem here. You should get a decent setup.
  6. Gasop

    Cold header tank Hot

    Is the cold from the shower mixer fed directly from the main or from the cold tank in the loft.
  7. Gasop

    Boss Therm 2 port valve

    Would be a good idea to check the pump. Could be that the hot water working on gravity only and you have not noticed this. When heating is called for then the boiler fires up and tries to work on gravity but of course going down on boiler stat as it is doing on HW but cannot circulate...
  8. Gasop

    boiler problem help

    Check 2 port valve if vented system on S plan or 3port valve on Y plan. These can jamb in the open position causing the problem you're experiencing. Best to do this when system cold. Set to H W only and feel if outlet of 2 port or port A of 3 port getting hot when boiler starts up...
  9. Gasop

    Immersion stat

    Make sure that the connections are as tight as possible. Loose terminals can cause extra heat. If you bought the Immersion from PTS then dump it and get another elsewhere.
  10. Gasop

    new loft radiators not getting hot

    Could be the system pressure a bit on the low side, try at about 1 1/2 bar
  11. Gasop

    Hot Water tap running dry

    Not possible. But if the tee is very high then air can be drawn in when the pump is in use causing air to be drawn in and causing an air lock.
  12. Gasop

    Hot Water tap running dry

    :shock: :shock:
  13. Gasop

    Flexible hoses in Central Heating system.

    They will do for a year or three but they WILL break down over time and cause blockages.
  14. Gasop

    PTFE required?

    No.
  15. Gasop

    leaking drain tap

    The boiler drain point of course :roll:
  16. Gasop

    leaking drain tap

    The washer is knackered and the jumper is stuck. Have new washer ready and drop system pressure to zero. Remove drain cock screw and pull out jumper with long nosed pliers. The washer may stay behind and you would have to poke about a bit with the pliers to get it all out...