Search results

  1. T

    Whole host of pitched to flat roof questions

    There is no point what so ever in discussing your roof until who ever did the drawing designs a sky hook to support the top 89x152 USB and the double bolted timber bressummers supporting the roof light. When you have a properly designed practical drawing then suggest you come back Regards oldun
  2. T

    Could I have some help please building a pitched roof

    Sorry posted twice. :oops: :oops:
  3. T

    Could I have some help please building a pitched roof

    Depth of extension 3700, assume cavity wall is 300, so less external skin, cavity and 50 mm ledger plate = 250 = 3450, for half run. Your true rise is 500 above existing roof to under side of first floor window sill less minimum of 150 for flashing = true rise of 350 therefore your true...
  4. T

    Could I have some help please building a pitched roof

    If you are doing this for your old mum. we can answer any question you throw at us, however we need the following information. Width of gap between your extension and next doors. Are your measurements external brickwork or internal floor area. Is the left hand flank measure 3010...3700...or...
  5. T

    Mixing Screed

    No. Not required. Regards oldun
  6. T

    22mm flooring chipbard

    Read our post to catlad. Regards trimmers, nine times out of ten you can still keep your joist centres round stair wells. On the tenth you slip in either one or two extra joists. One other point. If you are the coddy, it is for you to tell trades what you want and not for trades to tell you...
  7. T

    22mm flooring chipbard

    Comments like the above, only serve to highlight your lack of knowledge.. The specification that we posted is recognized practice, and is approved by both NHBC and LABC. The added advantages are that internal block work murder lift and bedroom lift can be built of off the new floor. The...
  8. T

    22mm flooring chipbard

    Posi or Eco joists at 600mm centres, 22mm Peel Clean T&G P5 chipboard, laminated and screwed as soon as joists are laid, all joints and screw holes water proofed taped and finished at tacking stage with 15mm plasterboard Joists should be laid correctly so that every 2400 board edge sits on a...
  9. T

    New build wc pipe connection

    Okay no problems. Post will be a bit long and detailed. You may have to read it few times for it all to sink in. First do not let Anglia Water do any of the work. If you are a doing a NHBC Self Build then do it all your self. If you are selling the plot on, then revise drainage lay out and...
  10. T

    New build wc pipe connection

    Sorry for delay.Have good days and bad days. Should be okay tomorrow. Oldun
  11. T

    New build wc pipe connection

    Did most of post to you. Went back to drawings to check a measure and found your prelim drawings. Our apologies to you for asking questions that we already had most of the answers to. We now note that it is only a w.c. and wash hand basin to the cloaks that is involved with the run in...
  12. T

    Pitch of this roof?

    If your measurements are correct, converted to metric = 3030 run and 685 rise = 12.7 degrees and slope of 3126. However if you have measured down the slope and not the run then pitch will be 12.9 degrees. You can tell just by looking at slope that it is approx 12 degrees Regards oldun --
  13. T

    New build wc pipe connection

    We do not know how knowledgeable you are so bear with us. Assume at present this is a private sewer, but will become public sewer when new unit is built. It is just not practical to try and get into existing manhole with new soil connection and you can not drop a new foul into existing...
  14. T

    New build wc pipe connection

    Masona, Have spent a while looking at drawings and afraid there are a few grey areas which we will tell you about in our next post. Mean time need a few more answers. In your sketch is the section drawing top right hand side showing 1250 deep the centre M/H in question. Is the channel of...
  15. T

    New build wc pipe connection

    Masona, Seem to remember you used to post a lot when we first joined the forum. Feel sure we can help you with your problem, but our old eyes are well past their sell by date and we can not get enough information of your drawing.. Answer following questions, and will see what we can do...
  16. T

    Cavity vs 140mm & Dot+Dab vs 190mm & Dot+Dab?

    Your original question was for AAC blocks and that is what we answered. We hate AAC blocks and run a mile away when we see them. Our choice of blocks on new builds or extensions is Plasmor Aglite Ultima They are made with expanded clay pellets and light weight aggregates leaving open textured...
  17. T

    How to get 20 years out of 150mm timber posts

    You asked a question, we gave you an answer. You did not like the answer, so use your own discretion. Regards oldun :o
  18. T

    Cavity vs 140mm & Dot+Dab vs 190mm & Dot+Dab?

    .Would appear that since answering your question, can of worms has opened. Will put you right. Put thin bed out pf your mind. It is as much good as a chocolate kettle. Use a 1.1.6 mix with splash of febmix. Yes AAC blocks are prone to movement and cracking render., however a 215mm block is...
  19. T

    How to get 20 years out of 150mm timber posts

    440x440mm brick pier sitting on 750x750x750 concrete foundation with 600 concrete with 100x100mm box section sat in concrete in middle of pier. Concrete to cavity on completion. Regards oldun
  20. T

    Flat roof timber size

    Span 3000. Imposed snow load 0.75kn/m2. Dead load maximum 0.75kn/m2 will require C16 47x150 @ 400 centres regularized to 47x145 Warm roof to garage is not required unless you intend to convert it to habitable use. Regards oldun
Back
Top