  1. T

    Ideas for construction method on new summerhouse

    Gary.. Timber frame Target 0.28 W/m2K. R + Resistance From outside to inside. External air 0.06 R 22mm timber cladding .0,17 R 25x50mm Vertical batten to form 25mm cavity 0.18 Permeable felt. 12mm ply or OSB 0.09 R 47x125 Stud work 12.5 foil backed plaster board 0..25 R...
  2. T

    Can i build my entire garage out of 7N blocks?

    Nothing to stop you using 7n dense but buy paint grade smooth. Only disadvantage you can only lay maximum 5 course before they are swimming every where. Regards oldun
  3. T

    bricklaying profiles

    You are not using them right then. We have tried them all, and Blake's are better than cut bread. On price work will pay for their selves in a week.:D Regards oldun
  4. T

    Stubby wall attached to pillar between garage doors

    Yes. It is providing a certain amount of longitudinal support and stability to the center pier. Appears it requires re building. Take it full height to 2100. Regards oldun
  5. T

    serviced plot expectations

    We would never buy a so called serviced plot and nor would 99% of small builders doing two or three units a year, however we would check that all services are available in close proximity to the plot. prior to signing contracts. Regards oldun
  6. T

    Advice please..Lime Mortar question for field wall rebuild.

    Before answering your question. 1 Who told you to use line mortar? 2 What is the average size are these so called smooth beach pebbles? 3 What is width of wall? 4 Is wall vertical on both faces or are faces battered? Regards oldun
  7. T

    Ideas for construction method on new summerhouse

    Gary, Thought you had gone walk about. Dead man. We use stiff concrete 450 wide and level from end to end down the edges, and possibly down the middle to split the bay and we screed of them. We use a 125x38mm aluminium rule laid flat and 900 bull float on 6m adjustable pole to finish.. As...
  8. T

    3 wind bracers in loft? Or is one a temporary brace?

    Semi detached. Assume standard Fink Truss, overall span 8 metres or less. Your photos are not very kind to our old eyes and your drawing is none to clear, however, it would appear that you have no wind braces at all. Will tell you what you should have for a Fink truss. Two number, one each...
  9. T

    Rubber matting to protect flat roof

    Aquapol is not a waterproofing solution for flat roofs, it is a completely different animal, however Aquapol do manufacture Cromapol Acrylic Water Proofing Roof Coating. This is a short term solution and carries no guarantee, and in our opinion is a waste of space especially over the top of...
  10. T

    Lintel installed upside down?

    Ronny, We do not believe we are wrong on this one, and you should know by now that we cover our backside every way but which. We did not mention any make of lintel, except for composite and non composite, how ever, on reflection, we do admit we should have said. (they are POSSIBLY non...
  11. T

    Pitched roof problem after problem! errrgghhh

    We often wonder just how much money people waste on working to a building notice, when neither they or their contractor know zit about construction or the BRs. Easy options first for you to put in front of BI for his approval. Repeat his approval. The list of Simpsons fittings that we will...
  12. T

    Lintel installed upside down?

    Sorry, but disagree with some of these posts. There are two types of concrete lintels and various grades If your lintels are two number 140x100mm deep then they are non composite lintels, and the reinforcement wires are approx 20mm up and 20mm down, so in theory it does not matter which way...
  13. T

    Red Ash

    Red ash, grey ash , black ash or any slag fill. To be honest, we would run away and live to fight another day. Regards oldun
  14. T

    Recess / Cut out of Concrete Floor

    Dig your recess into sub ground 50mm bigger all round than required and 300mm below bottom of new concrete base. Fill and level with concrete 300mm deep. Make up box to size required out of 25x150 using minimum amount of 32mm nails to hold it together. Rub some old engine oil on outside of...
  15. T

    Pitched roof problem after problem! errrgghhh

    Sounds like the house that Jake built. Are you on full plans or building notice? From scant information provided, we can only give a scant answer. Assume it is a vaulted lean to with shallow pitch due to the fact that you have to get under first floor window sill level. We assume vaulted as...
  16. T

    What on earth is my house made out of?

    101 is right it is Bungaroush shuttered walling and finished with a render. Only come across it twice in our lifetime, and first time we caught a cold on the work we priced, second time we run a mile when we saw what it was. Date of construction is right. Normally built of brick spread...
  17. T

    Brickwork & Pointing

    Much to strong for soft Reds and will dry out wrong colour. Use NHL 3.5 lime mortar Will dry out approx same colour Regards oldun
  18. T

    Advice on flat roof construction.

    Sorry for delay in coming back to you. 1200 polythene okay. 11mm OSB okay Facias. Difficult to explain this. Cut joists to size flush with external brickwork Mark down end of joist 75mm and 200 back (if 300mm wide cav wall) Cut this out so joist sits on internal wall and 75mm end of joist...
  19. T

    Structural steel work gone wrong

    There speaks a man of wisdom and knowledge. Regards oldun
  20. T

    Extension - insulation very expensive!? alternatives?

    Knew and old matelot who slung a mick of his rafters in roof space and slept up there. :roll: :o