  1. L

    Vivaro Problem - again

    Hello Burnt , I have a 53 plate Trafic , a good while ago I had a problem with it not starting , driven round generally ok when one Morning the Motor wouldnt fire up , It was spinning round but not firing atb all Got the RAC to check it out and they decided that the Crankshaft or the...
  2. L

    Torx bolt size

    Call the local Vuaxhall Garage and ask for the Workshop , if asked they will normally tell you Lucky
  3. L

    Moving a Tall Fridge Freezer

    Hello Bit of advice required , i need to move a Fridge Freezer , is it ok to put it in a Van but lie it down at about a 30degree angle as opposed to lieing it down Flat , The FF is approx 3 years old and is a Hotpoint if that matters If I lie it down , well cushioned will it be ok Gas Wise...
  4. L

    My illuminated bathroom mirror not working bulbs working

    Is it fed from above (Loft ? ) there may be an Spur Isolater with a Fuse in it that may have popped ? Or it may be sited outside the Bathroom ? Worth a looksee ? Lucky
  5. L

    Is this asbestos

    If the House is 1968 , i`d doubt it will be Asbestos , There was Supalux which contained a non dangerous Asbestos sustitute , then there was Masterboard , This Board was generally NOT waterproof , so I guess it would`nt be used a Tile Backing Board So my Money is on Supalux which will be ok...
  6. L

    spot lights in kichen

    Pound to a Ten pence Piece , It`ll be a B&Q type set , where you have a tranny feeding 4 Downlights as part of a Linked Kit , plus these Kits usually feed 4x20watt Lamps , customers feel that they are`nt bright enough , so they change the lamps to 35 or 50watt and knacker the Tranny , You may be...
  7. L

    RCD tripped - sockets issue?

    I`ve heard of Combi`s PCB`s causing E-Lkge problems occassionally , May be worth a shot disconnecting it - if its spurred off the Socket Circuit ? Lucky
  8. L

    RCD tripped - sockets issue?

    I`ve had problem with stupid things like Kettles being left in 1/2" of Water When checking Sockets check to see if the Back of the Box is dry , I had a fault on a job the other Day . somebody had fed an Outside Light via a spur , And fed the Cable through the back without a drip bend on...
  9. L

    Dimmer Switch query

    The Dimmer will have a Wattage Rating on it ie 250watts or 400watts if you are running say 4x50watt Lamps , I`d plump for the 400watt Model , I prefer to run the Dimmer on NOT the full wattage so to speak Lucky
  10. L

    Fused switch connector install help

    I`ll bet the Lamp is`nt sitting on the contacts properly , Fitted lots of these and occassionally I miss locating the Lamp on the Contacts Lucky
  11. L

    Infra Red Heaters in Verandah area

    Cheers Mate for the constructive Posting , Customer wants a Basic Installation , so the Proximity Sensors are out of the equation , had Planned to run the Cables from the C/U in a Conduit with drops down to the Switches , and Yes I`m with Napit.............. waits for the Flack !! :lol: ...
  12. L

    Infra Red Heaters in Verandah area

    Because quite a lot of other Guys do the same , and its good to bounce things off other People I`ve been Trading as a Sole Trader for 15 years and Sparkying since I was 16 coming up to 54 so quite a bit of Knowledge , but I can admit I don`t know everything and its good to see how other...
  13. L

    Infra Red Heaters in Verandah area

    Hello Fellas ( And Ladies should any be lost on here ) I`ve been asked to quote for Wiring and fitting 3x1.8kw Infra Red Heaters in a Verandah area ,Personally I would`nt bother with them but hey ho , Its work etc etc So the Verandah will be approximately 8m long across the Back of the...
  14. L

    Bulbs for downlights

    Try here http://lightbulbs-direct.com/ good prices and good gear Lucky
  15. L

    New ceiling light fitting - I have no earth!

    An extension Lead will do the Trick , Just put one of your Probes into the Socket Earth , then the other probe onto the Earth of the Plug Lucky PS- Yes that sounds liked the MET (Pic would confirm it )
  16. L

    New ceiling light fitting - I have no earth!

    Different Strokes for different Folks River :wink: Lucky
  17. L

    New ceiling light fitting - I have no earth!

    Ideally you need a Length of Cable(Flying Lead) long enough to go from the Light Fitting to the Consumer Unit area , Here you "should" find an MET (Main Earth Terminal) , Its a Block where the Earths will all be connected ie Earth from Incoming Supply Cable , and Earth cables from the Gas &...
  18. L

    New ceiling light fitting - I have no earth!

    If theres an Earth wire at the Switch , there`s every chance there`s a JB in the Ceiling void , You need to do a check in the void , If the backplate of the Light Fitting is large , maybe cut out a bit of the Ceiling and have a looksee , if there is and you can get it out , check it and also...
  19. L

    If cables beneath plaster should be protected by an RCD...

    Or surfaced mounted Clipped or in Trunking ? Lucky
  20. L

    Bathroom lights goone - downlights - what do I do!?

    Easiest thing to check is the Switch , maybe a loose Connection in there ........ ISOLATE 1ST ............. ie SWITCH OFF at CONSUMER UNIT Lucky