Search results

  1. G

    Potterton engineers on visits (Combi 80)

    The rules may state that anything outside the boiler is not covered by a call out but the engineers are human and will at lest change a fuse.
  2. G

    Potterton Prima won't switch off!

    Just read your problem again. Just wondering if you have a frost stat as this can keep the boiler on when it is very cold. If so a pipe stat would cure the problem.
  3. G

    Suprima 80 Problem

    Could be a pump problem and the boiler is actually working as it should.
  4. G

    Baxi Solo 3 60 PF

    Check the condition of the air pressure switch tubes & the plastic 90deg bend because if they are cracked or split your problem is the outcome. I take it the problem only occurs when the boiler has been on for approx. 2mins.
  5. G

    Potterton Puma 100 problem and pressure for shower

    The one at the top left is the auto air release. The flow hot water flow switch may have stuck which will over heat the boiler this may only need adjusting but probably will need to be replaced, as will the auto air release..
  6. G

    Suprima 80 Problem

    the thermistor is the likely component.
  7. G

    Baxi 105e.

    I would say that the dhw heat exchanger is blocked with sludge (dirt) from the heating system , these can be cleaned but it is easier to exchange them. Also get the return filter checked as these can also get blocked.
  8. G

    Help, potterton suprima 50 leaking water all over my kitchen

    From your pictures the flue has not been installed correctly as it is supposed to protrude more.
  9. G

    Pump for Potterton Combi 80

    If you use the cp63 head set it to speed 3 as this is the same as cp61.
  10. G

    Potterton Suprima 80L lockout

    The gas valve is ac.
  11. G

    baxi instant 105e

    Very reliable boiler if installed as per manufacturers instruction. It is a MUST that the system is properly flushed and that if fitted in a hard water area that a quality scale reduction device is used.
  12. G

    Potterton Netaheat 80E - Thermal trip

    Have you checked that there is water in the system.
  13. G

    Potterton Prima 40f boiler which does not ignite

    Yes. If the system was having circulation problems the o/h button would pop out ,so I don't think that this is the case with your boiler.
  14. G

    Baxi 105e Two problems – any ideas please?

    The problem with your hot water performance sounds like a common installation problem with this appliance in that the narrow water ways in the dhw heat exchanger get blocked ,either with scale (in hard water areas) or sludge from the heating system. This can be cleaned but i would recommend it...
  15. G

    Potterton Performa -no hot water or heating-Update!

    £220.00 including parts and labour. Probably a problem caused by lack of flushing by the installer, the narrow water ways in the hot water heat exchanger get blocked with debris from the heating system. 08706096096 is heateams number..
  16. G

    Potterton Prima 40f boiler which does not ignite

    Your symptoms do not make sense to me but if the pilot is still alight ( the electrode is still sparking) this points to either a broken down electrode lead or pcb. The bit that doesn't make sense is the over heat reset button allowing main gas to light as if the boiler has overheated the o/h...
  17. G

    powermax 155 scaled up

    A plate heat exchanger kit is available for this boiler it includes the blender valve this would be the best bet. The 155x can be purchased with a scale reducer kit with it but some unscrupulous developers did not take up the option make sure scale reducer is fitted. call baxi potterton call out...
  18. G

    Boiler swap from Suprima 40L

    The suprima must only be 4 to 5 years old why does it need changing :?:
  19. G

    Baxi 105e hw but no ch

    Your problem lies with the gas valve. I would suggest that the min gas setting is incorrect, it is not likely to be a wet problem as the boiler is failing on flame sensing. Setting the gas valve up is for a corgi installer ONLY.
Back