  1. G

    Potterton Puma 80 - pressure problems

    The pressure will creep up, as long as it doesn't go above 3 bar there is no problem. Have the expansion vessel checked next service.
  2. G

    baxi solo 2 50rs

    From what you say i would say it is the gas valve at fault.
  3. G

    Potterton Prima 50F Boiler won't fire up

    This problem is either the fan or pcb. Call heateam on 08706 096 096 as there call out costs include parts and labour.
  4. G

    imi powermax 135 boiler will not ignite

    But if you want it repaired call potterton.
  5. G

    Potterton Suprima 50 not lighting

    The whole gas control will have to be exchanged if the gas valve is faulty. Does the burner light at all?
  6. G

    Potterton Prima won't switch off!

    This could be due to the micro switch/s in the diverter valve/s sticking in the on position.
  7. G

    Baxi Solo 2 Boiler stopping

    Could be the pilot burner injector.
  8. G

    Potterton Combi 80 - noisy on start up.

    If it were air i would expect the noise to carry on during pump overrun.
  9. G

    Baxi Combi 80 Eco

    Try the return filter or that the return filter is not fitted on the flow pipe. this ia common installation fault.
  10. G

    Powermax 155x boiler..draining system HELP!!

    Should have drain offs on the system pipe work either by the boiler or on a few of the rads.
  11. G

    puma80 problem with low pressure

    Yes. There should be a filling loop , usually a braided metal hose (MAY BE DISCONNECTED) with two isolation valves at each, turn the valves on until gauge pressure is 1.5bar (when cold).
  12. G

    Potterton Combi 80 - noisy on start up.

    If the noise stops i would say its the fan. you could try wd40 but this will only last for a while call potterton (08706 096 096) as will repair cost will include parts.
  13. G

    Pott Netaheat 10/16 mk11F pilot burner problem possibly?

    Check that the m.v phial is actually in the pilot flame as the pilot burner could be at fault.
  14. G

    Baxi 80e/105e intermitant HW

    I agree, this problem is quite common because system are not flushed or inadequately flushed on installation. Would also check the heating return filter as this will also be blocked.
  15. G

    powermax 155 - HW ok but no CH

    The heating pump is wired to the cold start stat which is what determines wether the thermal store is up to temperature before letting the heating pump run. The problem is either the pump its self or the cold start stat. the blue box is connected to the dhw flow switch....
  16. G

    Potterton Puma: weird noises and pilot light

    Are you sure british gas fitted the right pcb as if they have fitted the one for the electronic model the boiler will over heat because the fan dosn't run constantly.
  17. G

    Baxi Combi 80 E

    The dip switches are not normally used for uk boilers but are required for the continent. Why are they there is for more technical people than me.
  18. G

    Potterton Profile Boiler

    Since when have B&Q had heating specialists in store :?
  19. G

    Potterton Lynx problem

    Sounds like scale in heat exchanger or pipe work to me.
  20. G

    Potterton Combi 80 Starts automatically

    The problem lies with the dhw switch witch is a sealed unit and can only be exchanged with part of the wiring harness. You will also need the pressure differentional so call baxi.