Search results

  1. G

    BAXI BARCELONA PROBLEMS

    Has the water leaked on to either the thermistor or o/h stat as i have come across similar symptoms.
  2. G

    Baxi 105e problems

    Does not require a drain down as thermistor fitted in a dry pocket.
  3. G

    Potterton Performa 24i HE

    A rated boilers are above 90% efficient , B rated are above 86% efficient (aprox)
  4. G

    Potterton suprima 30

    Try the electrode lead first as it could be broken down at the electrode end.
  5. G

    Potterton Prima F problem

    Problem probably lies with the electrode lead either loose or broken down.
  6. G

    Potterton Profile 40e

    Remove the plastic tray at the bottom of the appliance look at the serial number located on the right hand side behind the thermostat dial the first number is the year ,the second two numbers are the week of of manufacture.
  7. G

    baxi solo 2 50 pf

    Check that the pump is working and that there is no air trapped in it.
  8. G

    Potterton Puma 80e central heating - help!

    Had this problem today and it was a stuck pump and the water did work fine.
  9. G

    Noisy Boiler

    Kettling is caused by hot spot in the heat exchanger due to sludge or scale deposits. A new expansion vessel will not cure this problem & power flushing may cause more harm than good with you appliance as it will block the domestic hot water heat exchanger.
  10. G

    Baxi Solo 2 Boiler

    pf stands for power flue (has a fan). if there are no lights on the boiler but the programmer is ok i would suggest the fuse is ok, I would expect that the problem lies with the diverter valve or zone valves on your system as these are what will control the boilers operation.
  11. G

    Potterton boilers

    Before spending your £210.00 get your boiler engineer to look at the electrode lead at the electrode end , as breaking down of this lead can cause intermittent lock out.
  12. G

    Back Boiler pilot light goes out when the fire is turned on

    I would seriously call a corgi engineer as mixing the make of fire and back boiler is not normal/safe.The pilot outage could also be put down to a spillage of fumes from the fire.GET IT CHECKED.
  13. G

    drain cock

    Chris r on commision
  14. G

    Pilot viewing window

    Yes this job does require somone who is COMPETANT. :shock: :!:
  15. G

    potterton 28i combi more help please!!!!!

    If it was the expansion vessel i would expect the problem to be evident on both heating & hot water. This could be due to a blocked return filter (if fitted by installer) wich should be fitted to the heating return isolation valve, the problem you describe could be due to the filter being in the...
  16. G

    Baxi boiler works after reset, but shows fault once cool

    Am I right in thinking the fault occurs when demand is satisfied. Is your boiler the instant model? because I have never come across the problem you have described.
  17. G

    potterton 28i combi more help please!!!!!

    Drain the boiler only ,this boiler has isolation valves (which do not leak when moved) and a drain cock inside the appliance under the pump. When boiler is empty check the pressure in the expansion vessel is 1Bar. When you say boiler is operational is it running heating or water.
  18. G

    Baxi Solo 2 50RS

    rs = room sealed no fan pcb or aps., pf= power flue has fan ,aps & pcb...
  19. G

    Baxi Solo 2 50RS

    If it is the rs model it does not have a pressure switch.
  20. G

    Powermax 135

    The waranty on appliance run from when the first tennant moves into the property by this time it has bee used as the site office/hut or show house for a year.