  1. G

    Is my heating pump faulty ?

    sound as though the pump is jammed, you can free this by undoing the screw or nut in the center.be ware hot eater will come from this so be prepared, if the pump has a nut undoing it will free the pump but if it has a screw you will need to use a screwdriver to spin the end of the motor.
  2. G

    Powermax 155

    Depending on what type of property you live in , the 155 should be fitted with a anti-gravity valve fitted on the heating flow pipe to stop gravity circulation when heating not on. This is refered to in the installation instructions.
  3. G

    Potterton Kingfisher not firing

    Is the boiler getting a switch live? If it is could be a gas valve problem.
  4. G

    Baxi Solo 3PF - blowing fuse

    I agree. The fan is definatly a suspect but it could also be the pcb.
  5. G

    Baxi Bahama 100 LEAKING?

    the water can run down the outside of the combustion chamber and collect on the seam of the expansion vessel. its is better that the auto air release is checked first as it costs allot less.
  6. G

    Central heating inhibitor - how to add to sealed system

    these kits are basically the same but inhibitor is put into rad bleed valve.
  7. G

    Baxi Bahama 100 LEAKING?

    if it not leaking form yhe schreder valve on the expansion vessel (the red thing) in my experince it is probably coming form the auto air release located on top of the appliance on the right of the flue elbow.
  8. G

    Baxi Intellistat is it worth it?

    i concur with gaz on that one.
  9. G

    Central heating inhibitor - how to add to sealed system

    both fernox and sentinal now have packs available for dosing systems and that are available at homebase , b&q ect.
  10. G

    potterton 24 performa

    YOUR DOMESTIC PLATE HEAT EXCHANGER IS BLOCKED WITH SLUDGE/SCALE ON THE PRIMARY SIDE, THIS IS NORMALLY DUE TO LACK OR INADEQUATE FLUSHING ON INSTALLATION. MOD see item 6
  11. G

    relight baxi wm40 boiler

    IS THE BOILER A PF MODEL? MOD see item 6 turn the caps lock off
  12. G

    Potterton Puma 80 combi

    PROBABLY NOT THE DIVERTER VALVE BUT THE DIFERENTIONAL PRESSURE SWITCH AS DIVERTER WILL SWITCH TO HTG WHEN NO DHW DEMAND.
  13. G

    Potterton Puma 80 combi

    i would say ,from exprience, that it is one of 2 problems either the pump or diverter valve ,if not the pressure.
  14. G

    Baxi combi boiler central heating problem

    probably diverter valve head or cartridge , from your discription.
  15. G

    potterton 80 shutdown when shower on

    if it is only locking out on the bath mixer it is that that is at fault not the boiler. the washers in the tap are expanding causing flow rate to drop overheating the boiler. re-washer taps or change if a ceramic disk mixer.
  16. G

    POWERMAX 155

    the lock out light has nothing to do with overheating or presure loss, it only goes to lockout for ignition problems. this could be anything,gas valve , control box or even a fluing problem.
  17. G

    How to relight a Potterton 80

    if your land lady is lazy be lazy paying rent, i bet she will soon sort the boiler out.
  18. G

    New Boiler

    no one asked where in the uk you are, in scotland the new part l regs do not apply. as for larger manufactureers not coming out to warranty calls this may have been the case in the past but not today.