  1. G

    Ademco ContactID code descriptions

    When systems are 'bells only' the panel can be configured to force a zone omit when the zone triggers multiple times - the number of times is programmable. Say a door is left ajar, and it causes an alarm trigger. The alarm will trigger and bell sound for the bell duration and then the system...
  2. G

    Ademco ContactID code descriptions

    If you google for the Galaxy Flex installers manual, you'll find the codes page 195 onwards. They're mostly generic across the Galaxy range - some of the event log text differs between panel types and firmware versions, but the SIA and contact codes should be stable...
  3. G

    Honeywell Galaxy 2-12 C012

    As per my PM, you'll need the engineer code to change the battery and clear any battery fault or lid tamper.
  4. G

    Honeywell Galaxy 2-12 C012

    I've sent a PM.
  5. G

    How do I bring this alarm system back

    PM me and I'll take you through the code only default process to get this going again.
  6. G

    Another Galaxy 48 ADT reset / crash / factory default thread

    You need to enable engineering access using the manager code first. So, manager code then menu 48 and enable access, then esc out of the menu and enter as engineer. If you are starting from default, then get the SPI key to upgrade to non ADT. It will be easier in the long run and get you on...
  7. G

    Honeywell Galaxy Flex GSM/GPRS A801-00-01 Firmware update from V2.04 to 2.07

    Ouch. Pm me if you need the fw files. Otherwise, use a 4G router for broadband and an a083-10 v4.16b2 ethernet module.
  8. G

    Honeywell Galaxy Flex GSM/GPRS A801-00-01 Firmware update from V2.04 to 2.07

    Hi, a fix was added at version 2.06 to reset the modem if it ever goes into an unresponsive state. You should improve the signal and also update to the latest version 2.07 for the best results.
  9. G

    Replace Honeywell Galaxy G2-20 alarm system

    There's the option of adding the SelfMon VMOD module to the Galaxy G2 series. This enables the option of remote control via app, or even better if you have VPN, direct back to the panel via browser. See www.SelfMon.uk for details. You can always change the controls for newer Honeywell Galaxy...
  10. G

    Moving Home - Alarm System

    Hi, yes, the gsm/gprs module will work and alert through a power outage. I would just use Ethernet and then have the GSM SMS as a backup if the Ethernet path goes down. You can control the Flex panel via SMS too. If you do want to use a data SIM, including connecting the app back to the panel...
  11. G

    Honeywell - Tuxedo vs Galaxy TouchCenter

    A menu option appeared and disappeared between revisions. It was never documented, so I don't know if it was just part of the touch center plus introduction.
  12. G

    Wiring for future alarm system

    You may want to sketch out your plan and post to get further advice based on your layout and intended sensor / device positioning.
  13. G

    Wiring for future alarm system

    Select a suitable location for the control panel. Preferably not a boiler cupboard that will be warm and cause the backup battery to dry out faster. Wire each sensor with its own cable in a star formation back to the panel. Each sensor will have its own zone which can be programmed to any...
  14. G

    Galaxy flex100 beep from alarm box

    Yes, but that looks okay. I'd probably need to pull the settings with RSS to work out what's going wrong.
  15. G

    Galaxy flex100 beep from alarm box

    What function do you have the outputs programmed as?
  16. G

    Galaxy 2-44 - Siren can't be turned off

    I've seen a couple of panel PCB's damaged by lightning strikes to the PSTN lines in the past. If no wiring has been damaged / touched, then the flashing stars are a sign that the PCB in the panel is not booting up to communicate with the keypad. The keypad shows the stars when no bus...
  17. G

    Galaxy 2-44 - Siren can't be turned off

    Is the alarm connected to an old copper phone line? If you've disconnected the 12v internal battery and powered off for say 20 seconds and on again and the panel still isn't booting, then the panel may have been damaged. The external SAB in the sounder should cut out after 15 minutes or so if...
  18. G

    Honeywell RSS Update Patch

    I'll PM you