  1. N

    Gas fires without MI's

    Even its just for a landlords certficate?
  2. N

    Gas fires without MI's

    I thought you had to issue a warning notice whether they allowed you to isolate or not? I didnt think we had an option but to issue one It wasnt a service, just a normal gas safety check, but I guess the same still applies doesnt it? Actually, you wouldnt need the MI's when doing a...
  3. N

    Faulty Baxi 105e / Flashing "fan / flue" (50 degre

    Could be the air pressure switch. I replaced 2 of these on this boiler last week
  4. N

    Gas fires without MI's

    Just done a landlords certficate and there was a gas fire in the lounge but they didnt have any MI's for it. It was a wickes one. They said they hardly used it and i did a flue flow test which was fine However, it was a coal effect fire, and I remember my teacher on the course saying that the...
  5. N

    Open vent into cold storage tank

    Just had a call from a client who said somebody had been round to service the boiler (but couldnt do a landlords certificate :?: ) and said that the open vent from the boiler was going into the cold water storage tank 1) Does this come under the gas side of things on a landlords certficate...
  6. N

    Gravity fed to fully pumped

    I intend to do what your first bit says, but Im also going to make the system pressurised, so I can get rid of the CF and OV Does that sound ok?
  7. N

    Getting your own Corgi

    It'll still easily pay for itself. Even if you was only doing 1 job a week,within a year it'd make you double what you paid out for (inc insurance and accountant fee's)
  8. N

    Gravity fed to fully pumped

    is that a serious "sounds good" or a sarcastic "sounds good"?
  9. N

    Getting your own Corgi

    I work for a firm and I got my own corgi at the start of september, and it had paid for itself and the insurance within 3 weeks. I paid £425 for initial registration and 1st year membership, and about £550 for the insurance, which was also through corgi Your company wont need to know...
  10. N

    Gravity fed to fully pumped

    I wouldnt have a 2 port, id have a 3 port
  11. N

    Gravity fed to fully pumped

    How about if I went fully pumped with a 3 port and pressurised system, that would be quite straight forward wouldnt it?
  12. N

    Gravity fed to fully pumped

    So are you saying to basically keep the system as it is (gravity hot water, pumped central heating) and just stick at cylinder stat in and a 2 port on the hot water side? Wouldnt it just be just as easy to stick a 3 port and have pumped hot water too? The pump will have to be moved from its...
  13. N

    Gravity fed to fully pumped

    Whats c plan? Ive only ever heard of s and y!!
  14. N

    Gravity fed to fully pumped

    Went and looked at a job today. The fella is redoing his kitchen and currently has a floor standing boiler in the kitchen, which is gravity fed hot water. He would like this removed and a wall hung boiler put in. He also has a pump on the shower in the bathroom, which has all now been boxed and...
  15. N

    Vaillant Turbomax VUW 242E not firing

    Sounds like the gas valve to me
  16. N

    Fuses blowing in pcb's

    And what about if one of those components is blowing the actual pcb, not the fuse? Surely you wouldnt leave them connected would you?
  17. N

    Fuses blowing in pcb's

    and if you read the post youre referring too, you will see that I did that. You would have also have read that with the leads unplugged from the solonoid, the voltage on the leads stayed at 240V. You would have also read that when the leads were put back onto the solonoid, the voltage kept...
  18. N

    Fuses blowing in pcb's

    Thats funny because if I remeber correctly, most people were saying it was the gas valve, but I went for the pcb and it worked :? +++++++++++++++++++++++++++++++++++++++++++ oh and corgiman, youre a top man, I wish the rest of them on here were like you, willing to give us newbies to the...
  19. N

    Fuses blowing in pcb's

    Test the neutral and make sure the reading isnt 240V
  20. N

    Fuses blowing in pcb's

    In my case, that would mean a new pcb!!