  1. K

    fcu or 20a dp switch for kitchen appliances

    securespark and bas...... you sure have posted enough on here.... how long you been members
  2. K

    fcu or 20a dp switch for kitchen appliances

    thankyou bas I'll use the dp switches By the way bas you seem to upset a few people on here and you know your stuff...
  3. K

    fcu or 20a dp switch for kitchen appliances

    Which is the best way? Appliances in kitchen......Isolator switches above work top then down to a single socket for appliance. Any preferences between using FCU'S or 20A double pole switches for my isolators or will either do? Regards Katron.
  4. K

    60A main fuse 100A breaker?

    removed intake fuse and looked.... I know you shouldn't but you need to know for when filling out an EIC anyway..and leccy board aren't helpful... Seen quite a few intakes saying on fuse holder 100A when 60A insde and vice versa.
  5. K

    60A main fuse 100A breaker?

    yes have applied diversity, will explain to customer again, Thanks for the quick response!!!! :D
  6. K

    Testing Supplementary Bonding

    yes just test between extraneous conductive parts and also the cpcs from each circuit in the bathroom and ecp's....read the figure should be less than 0.05 ohms
  7. K

    60A main fuse 100A breaker?

    Just a quick one, in the middle of a job, an outside light on it's own circuit...problem is that the main incoming fuse is 100amp and the fuse board is an old wylex 3036 rated at 60 amp, maximum demand to be 70A, advised customer to replace board and tails, but has refused. Should I carry on...
  8. K

    fan in toilet?

    Does a toilet in a new extension ( being built in the next 2 months ) require an extractor fan, even though it will have a window that opens? Advice greatly appreciated Katron
  9. K

    Mounting accessories in kitchen cupboards

    Can somebody please tell me if it is against regulations to mount sockets inside kitchen cupboards, as i was under the impression it was against building regs or whether that was a guide...or you have to fix them to the fabric of the building. Thanks Katron
  10. K

    Pelmet lights req socket but on lighting circuit.

    Thanks for your advice plugwash
  11. K

    Pelmet lights req socket but on lighting circuit.

    Like you said its not ideal, but if I can get away with it, great... Thankyou RF
  12. K

    Pelmet lights req socket but on lighting circuit.

    Just 1st fixed a kitchen, and client instructed me to have individual switches for the cupboard downlighters, under pelmet lighting and kick board lighting, all 12v....so I have put my drops in, and found out the kick board lights have got a plug in transformer(adaptor) which feeds the block for...
  13. K

    Sockets located in new kitchen

    It is a guide to the building regs, so if we follow it we should be ok, right?
  14. K

    confused with a rewire please help

    Access and facilities for the disabled
  15. K

    Sockets located in new kitchen

    I was wrong sorry, but in the green ' electricians guide to the building regulations ' page 56 ' wiring accessories should be mounted on the building fabric and not on the kitchen furniture'. It does say actually 'General guidance' in which case is it ok to do?
  16. K

    confused with a rewire please help

    My mistake....its Part M of schedule 1
  17. K

    Sockets located in new kitchen

    In part p it states that wiring accessories should be mounted on the building fabric and NOT on the kitchen furniture.
  18. K

    confused with a rewire please help

    I understood it that heights of switches and sockets etc, to comply with part p were for new builds ( min 450 max 1200 ), and for rewires of rings should be positioned so not less accessible than before.
  19. K

    combi boiler 240v between neutral and earth

    thankyou for that.
  20. K

    combi boiler 240v between neutral and earth

    been around to a friends house following a heating engineer. Engineer told him possible loose connection, so I went around and indeed it was in the neutral bar in the cu. Reconnected, did r1 + r2, ins res, and zs, everything was fine and worked ok. My question is why would it show a 240v...