  1. T

    Easy BT drop wire question for you all

    I take it that the orange and white wires are not connected to anything ???yes the working pair should be on the screws but I would put green on A and black on B . The orange white is the first pair in the dropwire and the green black is the second pair and would only normaly be used if you had...
  2. T

    ideal isar

    Its a wilo pump , will this also be causing the rcd trippping out , it must be because when it is heating with the display showing t it runs ok as soon as it swiches to c the rcd trips
  3. T

    ideal isar

    Went to an isar which is leaking water from the pump . so ive ordered a new pump , will it come with the manifold???? as the old one is leaking between the manifold and the pump . Also I was hoping to leave them with it working just needing re pressurising untill the new pump arrives but when it...
  4. T

    help - i am cold - i have no heating! classic FF370

    If it has tripped just push it back in to reset it then try the boiler again
  5. T

    Moving external telephone cable

    As an openreach engineer if the tree is on your property , you would now be charged for any damage the tree causes to the wire as it is your responsibility to cut the tree and keep it off the wire !!!!!
  6. T

    Worcester 24i wots going on?

    Is the pressure guage reading about 1 to 1.5 bar ?? does the reset button need resetting ??? , doe sit work on heating or is it just the same?
  7. T

    Removing a room thermostat

    Yes , where the red is connected in the wiring center and where the yellow is connected put a link wire between these two terminals or you wont get any central heating
  8. T

    Removing a room thermostat

    If they are the wires from the stat the blue can just be disconected as that is neutal ,green can be disconected as that is earth and you wouldn need to put a link in between red and yellow to complete the heating circuit as one will be the programmer calling for ch and the other will go to fire...
  9. T

    trv broke in kitchen but pipe not hot either

    No because the valve is stuck shut the pipe will not get hot upto the valve as there is no floe through that part of the circuit
  10. T

    Baxi Solo 2 CH not working

    Sounds like not enought water in the system if it is fed via a small tank in the loft check that the ballvalve hasnt stuck and there is water in the tank , if there is it could be a blocked feed from the tank into the system .
  11. T

    Moving external telephone cable

    in theory you arnt allowed to re route this but officially you would be charged at least £150 plus , get some offical cable in either black , brown or white and no one will be any the wiser . :lol:
  12. T

    BOILER. please help

    If the fan isnt coming on then the pilot light will not light as it has not proved it is safe to light , have you checked power supply and fuses etc???
  13. T

    Laying carpet underlay

    Why have you posted this in the Plumbing section ?????????????
  14. T

    TRV 2 way

    the trvs are not linked to yuor room stat , the room stat should turn the whole heating off when the temp is reached , so either the room stat is faulty or wired incorrectly.
  15. T

    Odd (maybe not) telephone question

    Its best to just run a temporary wire , if you went down the official route it would cost you a fortune , just run your temp wire and connect it and keep the connections dry .
  16. T

    3 new radiators all half cold since installation

    How about getting your installer back to sort it out
  17. T

    gloworm 30ci will not build up pressure

    Sometimes the blue part moves but doesnt turn the shaft , take the blue head off and use an adjustable spanner on the shaft .
  18. T

    Replacing external BT/openreach cable to NTE5

    I have sent you an email hopefully!!!! if you havent recieved it let me know on here.
  19. T

    Replacing external BT/openreach cable to NTE5

    If there is no fault condition on it openreach certainly wont replace it free of charge and if you had damaged it by having a door or window fitted then we would certainly charge for that as well . Reasonable wear and tear is free but only if your line is actually dead or noisy . I am in crewe I...
  20. T

    Replacing external BT/openreach cable to NTE5

    I have some official cable , where in cheshire are you ???? the cable you suggested isnt really external cable and will go brittle and the insulation will crack.
Back