Search results

  1. R

    Gas pipe on the outside of the house

    Depends on how many pikies you have around by you. Would seriously consider running steel externally now where doing long external gas runs owing to the amount of metal thefts.
  2. R

    Grundfos 15/60 Pumping Downwards

    grundfoss state that this is a non prefered option and should only be done if there is a suitable means of venting air directly before the pump. The reason being that owing to the design of the pump body, air can become trapped. Ideally the feed/vent wants to be on a horizontal piece of...
  3. R

    Baxi Solo 18HE keeps locking out.

    3months? you must have had a good batch
  4. R

    Water dripping through tundish - Megaflow Unvented Cylinder

    really should spend longer reading posts. sorry you've already replenished gap. in which case your plumber needs to do some investigation into whats happening to the pressure and temperature of the water in the cylinder. your doing the right thing in getting the plumber back to do this for you.
  5. R

    spliting the system

    could do with some details regarding the current system you have
  6. R

    Water dripping through tundish - Megaflow Unvented Cylinder

    instructions for replenishing airgap are on front of cylinder. fairly self explanatory.
  7. R

    Megaflo 210 - how do restore pressure?

    cba to read all posts. megaflo doesn't use external vessel for exp. red vessels rpiamrily used for htg. would suggest is htg pressure that has been lost.
  8. R

    soil vent pipe cover

    are you sure you've got a bird cage and not just a cap end?
  9. R

    Remeha Avanta 18V

    sorry. haven't read all the posts. Pressing the reset button does not return the boiler to factory settings. If you change he display setting so that it stays on, it will tell you at least what mode the boiler is in. ie pre purge, ignition etc. (oops just notice boilerman2 had expanded on...
  10. R

    New Pump in Combi - but CH still not working ?

    blocked return filter on blr? dependant on location of fill loop
  11. R

    Remeha Avanta 18V

    firstly turn the display on in the user settings. then check that all the user settings are as they should be for your blr. turn on your controls so that they are calling for heat. what mode does your user control tell you that the boiler is in? Even if it doesn't help fix it, you can really...
  12. R

    diagnosing a problem and rectifying the fault

    well thats a first. something that I agree with tickly-t on. I'll be ranting about british gas and cc's next
  13. R

    HELP: Baxi Boiler or Bristan Mixer at fault ?

    most likey the diaphragm on the pressure differential has split or stretched according to the first lines of your description.
  14. R

    main 24 he flame fail

    I have seen the light and shall now be answering all posts using only punctuation marks, numbers and the cyrillic alphabet
  15. R

    just to say hello

    she also takes a long time to get to the point. ermm so I've heard. ..
  16. R

    Baxi Duo Tec frozen - ideas needed

    this post is f*ckin hilarious
  17. R

    Main combi 24 HE issues

    don't like to say it but..... TOLD YOU SO!!
  18. R

    Baxi 105he instant

    piped up back to front?
  19. R

    Hot Water Tank

    scaled up coil?
Back