  1. R

    Baxi bernuda rad system

    take airpins out completely. clean hole with a pin, push air pin back in quickly when air starts to escape
  2. R

    BG slapped notice on boiler in 1980s flat.

    possibly change in regs as per ventialtion requirements as less than 90% of required free air now at risk, where it may previously had been only NCS? bloody b.g going around applying the gas safety regulations as if it's the law! Who do they think they are?!
  3. R

    potterton boiler flame failure

    has it been serviced recently. may be an idea to get high and low burner pressures checked? can't think of an immediate fault that would throw up this symptom at all
  4. R

    Baxi 105e, no CH, uuurrgh...

    if your dhw light is on constant then blr thinks there is dhw demand. it will therefore not allow the heating to come on as dhw takes priority. as ngff says either siezed diverter/pressure differential spindle or a duff dhw microswitch.
  5. R

    Baxi 105e, no CH, uuurrgh...

    internal timeclock-grasslin type? if so check between N and both sides of switch. should have 240 L-N on clock switch (not between tor live and neutral on clock) sorry if you've saidabove what your set up is-too late and too tired to read
  6. R

    Baxi Platinum Plus - problems with plate heat exchange

    Looking at the m.i's and having read what mickyg and some of the other chap's have said, then I would be looking into whether or not expansion is able to take place in the cold main. If you have a look at the manufacturers instructions regarding this there is a good illustration of what MickyG...
  7. R

    Baxi Platinum Plus - problems with plate heat exchange

    Ihave a sneaking suspicion that your hot water cylinder is an unvented system that is being heated indirectly by your blr. I also suspect that form what you have said the dhw to the blr is perhaps being fed either from the cylinder or is perhaps teed in somewhere on the hot water. I would...
  8. R

    failrly new gas fire no longer lights

    apparently you need to be at least 4 doors away
  9. R

    Remeha Avanta 24S CH fails to start intermittently.

    may not be the stat at all. Programmer, wiring, or most commonly the zone valves. I would look at your valves first.
  10. R

    failrly new gas fire no longer lights

    but I bet you had gas though
  11. R

    suprima 80L trouble!!!

    One of our lads pointed out that the majority of the ones that have still got the original board in tend to be those installed in garages or cooler utilities. Can't say I have noticed a connection myself but thought it may be an interesting point.
  12. R

    Such things as 'fault finding & diagnosis' plumbers...?

    trap loss by compression or induced siphonage? May want to take a look at building regs approved doc h(?) for an idea of guidlelies regarding soil and vent pipework do's and dont's. Many plumbers disregard the importance of correctly installing drainige pipwork correctly- and fewer still go...
  13. R

    Potterton Statesman 45/50 oil boiler.

    You can write what I know about oil boilers on a postage stamp, but you can find all the svc/maintenance manuals on Baxi partarena complete with list of parts for said blr
  14. R

    suprima 80L trouble!!!

    ah. thought i'd never seen a part no. for them. never seems to stop people fitting them though judging by the posts on here. cheers nickso
  15. R

    Amptec Model 600 wont switch off!

    have a look in the m.i's. it should show you the terminal connections that you make he stat across. check you haven't left the link in!
  16. R

    suprima 80L trouble!!!

    make sure they fit part no 5111603 and not simply old replacement board
  17. R

    moving a boiler into the loft space

    plus i HATE blrs in lofts with a passion. Not to mention frost stats, pipe stats as well
  18. R

    moving a boiler into the loft space

    biggest problems is not being able to keep an eye on it. having to access loft to check pressure etc. also you may hit problems if your htg is maintained by large national firm with regard H/S. eg lighting, boarding, access, ladder. carrying certain parts into loft etc etc
  19. R

    Amptec Model 600 wont switch off!

    have you tried disconnecting th timeswitch connections at the blr terminal to see whether the fault is on the unit or timeclock?