Search results

  1. S

    Bats.. question to roofers

    We tried an ultrasonic deterrent but found it didnt deter bats from entering our attic. In the end we managed to get rid of them by providing alternative accommodation. We put bat boxes high up on the gable wall near where we think they enter and in trees in the garden. After a few months the...
  2. S

    Blown Worktop or Just Too Tight?

    Were these joints assembled with biscuits? If not then they have probably just moved - nothing to do with bolt tension or water ingress.
  3. S

    Excessive Gas Consumption - Not sure what to try next!

    Our 1960s oil fired 3 bed home uses about 350 Litres of oil in an average winter month. Thats about 3500 Kw and sometimes if the temp drops below zero we fire up the coal fire but no idea what that adds to the Kw total.
  4. S

    BGas say our 5amp fuse feed has damaged boiler.

    Assuming the boiler is connected to a FCU you could try replacing the FCU fuse, unplug or disconnect the power cable at the the boiler (safety the exposed wires if you do the latter), then switch on the FCU and see if the fuse blows.
  5. S

    Room thermostat to call pump only

    Back in the day a lot of these old systems were originally connected to coal stoves and had a towel rail on the primary as a safety feature. If you have a towel rail in the bathroom might be worth checking to see what its connected to.
  6. S

    Room thermostat to call pump only

    So what you are trying to do here is constrain the HW temperature down to a safe level and prevent convection heating the radiators in the summer. Is that right?
  7. S

    Riello 2.2 burner

    Well with a 4ft header I dont know how likely it is that air is somehow finding its way to the pump inlet. The way these pumps operate is that they have a far greater capacity than the burner can ever need and they spill back the surplus to the pump inlet. That means the pump heats up quite...
  8. S

    Riello 2.2 burner

    Personally the only time Ive seen a pump delivery pressure fluctuate like that is when it is purging air after the fuel supply has been re-connected after maintenance.
  9. S

    Kia Picanto parasitic battery draw

    Thats what happens with modern cars. What I do is a regular battery charge once a week. I just leave the battery on charge overnight every Sunday.
  10. S

    Camray 5 Oil Boiler Summer v Winter Setting

    The winter position will run the flow temperature at maximum but the hot water will rise to the same temperature which can be hazardous to say the least. You might have some device fitted either electrical or mechanical to control that. If not its best to turn down the flow temp a bit if you can.
  11. S

    Washing machine banging noise

    Sometimes what can happen is that the drum spider fails. That is a three legged frame structure that connects the drum to the drive. They are generally made out of rubbish material and it may be that one or more of the legs has failed allowing the drum to become unbalanced.
  12. S

    Riello 2.2 burner

    Hopefully it will be something straightforward and cheap to fix but I think the main pointer here for you is the lack of lockout. Any failure of the start sequence should lock out the burner and that lockout is a function of the controller. Anyway good luck with your troubleshooting.
  13. S

    Riello 2.2 burner

    I remember several years ago having a similar problem with a Riello burner where it kept repeating the ignition cycle many times before it eventually settled down and kept running. No red light or lockout. If I remember correctly it turned out to be a fault with the controller.
  14. S

    CH problems

    I have no idea about the bills but If the heating system was working OK for the previous owner then maybe he was operating the boiler in non-condensing mode.
  15. S

    Maximum flow temperature

    If you have a modern highly insulated home then you can reduce the flow temperature to capture the latent heat that would otherwise vent to outside. On an older property you will probably need to maintain a higher flow temperature which will result in lower efficiency.
  16. S

    Led stair riser profile dilemma

    A copper channel can be annealed with a blow lamp allowing it to be formed to a shape before it eventually work hardens.
  17. S

    Electric Metter reading

    Even meter readers get these wrong.
  18. S

    Landis & Gyr 1987 Central Heating Controller

    Single screw to loosen underneath and the controller then just lifts away and you can replace it with a Drayton LP722 or similar that uses the same back plate.
  19. S

    Digital shower- pumped- issue

    Are the little supply valves on the hot and cold connections to the controller fully open?
  20. S

    Tooth brush charger in bathroom cabinet

    Had a rummage through my archives and found an assembly instruction for boxes Pt.Nos. EBE-60R-SW and EBE-120R-SW which were installed in the UK but guess they are now discontinued. Might be worth searching on line for second hand.
Back