  1. R

    motorized valves

    Motorized valves come in two flavours: 2-port, known as 'zone valves' (a simple open/closed piece of pipe), and 3-port (a fully controlled T-junction). There are two varieties of 3-port valve, mid-position and diverter. With a mid-position valve the middle port is connected to flow from the...
  2. R

    Fitting an electric shower - regs

    What are the regs regarding the fitting of an electric shower? The obvious one that comes to my mind is do i ned to be part p qualified and what other regs do i need to watch if any???
  3. R

    Shower joint leak/exposed valve

    and no dont put on two olives it wont work
  4. R

    Shower joint leak/exposed valve

    wrap ptfe tape around the front of the olive and over the front part about 3-4 turns and try that. [/img]
  5. R

    blocked waste drain

    have you checked the outside drain? is this blocked again
  6. R

    Help with bath tap shower mixer needed !

    yes go for the pump on that site that you showed me, its should near enough make the pressures equal. Remember double check vales if the shower is of flexible hose (water regs)
  7. R

    Help with bath tap shower mixer needed !

    ok what about the cold water
  8. R

    fitting a pump to boost shower pressure

    r15.14c of water regs book states a double check valve is needed should the spill over level be reached by flexible hose to protect against cat 3 / 5 fluid risks if hose is able to reach spill over levels of toilet = fluid cat 5 bidet = fluid cat 5 or bath = fluid cat 3 then double check be...
  9. R

    fitting a pump to boost shower pressure

    but make sure you dont pump mains fed... only pump cylinder hot water or cold can be pumped as long as from a cwsc tank normally in the loft and not the rising main
  10. R

    socket spanner size for bath tap monoblock

    chris i was thinking the same..
  11. R

    fitting a pump to boost shower pressure

    is the shower head of rigid construction? if not it will need a double check valve to prevent backflow. (if unsure stick the double check valves on anyway better safe than sorry) if its mains pressure it will need to be a thermostatic mixing valve, Yes the pump will be ok to pump all or just...
  12. R

    socket spanner size for bath tap monoblock

    have you tried any imperial sockets
  13. R

    Help with bath tap shower mixer needed !

    yes a single pump will be good, have you checked what the hot water pressure is running at without a pump?
  14. R

    fitting a pump to boost shower pressure

    have you thought about putting the pump next to the hw cylinder thus out the way and powers all hot water
  15. R

    Help with bath tap shower mixer needed !

    also make sure you have a min 150mm head instead of the normal 1m, this allows the flow switch to open when the supply is turned on :P
  16. R

    Help with bath tap shower mixer needed !

    its possible to fit a shower pump to the hot water to increase the power, but dont fit a pump on to the mains suppy (cold) unless this is coming from the cold tank in the loft.
  17. R

    Torbeck bottom entry Valve problem or not??

    found the Problem, it was a very slow leak on the siphon, was hard to spot but got there in the end.. Thanks all.. :wink:
  18. R

    powerflush machine which is best buy....

    cheers i will take a look mate.