Search results

  1. P

    Video: Promax SL issue

    Have the lead and the connections on top of the condensate trap checked.
  2. P

    New property - can't figure out electrical heating system

    It looks like your on a communal heating system, the box is a heat exchanger with a heat meter on the front of it, the immersion switches should be for back up.
  3. P

    Mixer tap flat plinth/base ring

    https://www.ebay.co.uk/itm/323754196211
  4. P

    Central Heating Only Coping With Heating 3 or 4 radiators

    Does the system have an automatic bypass ?
  5. P

    Valliant EcoTEC plus 824 RI: Heating not working

    If i t starts with an 8 its a combi, could be a stuck diverter valve at a guess.
  6. P

    Valliant EcoTEC plus 824 RI: Heating not working

    Its a combi boiler chris..... dont know where the op got the RI from anyway check that the valves under the boiler to the heating circuit haven't been accidently closed.
  7. P

    Adding UFH to Y plan (radiators removed)

    Why use an s plan ? get rid of the 3 port and just have a two port controlling the hot water, the op hasn't wired a hot water off so the valve will stay in ch, probably find his boiler has shut down of the overheat stat.
  8. P

    Adding UFH to Y plan (radiators removed)

    I haven't followed your wiring description but it does not sound right also the three port does not return to hot water after demand , three ports stay in the last position they where in when demand has stopped.
  9. P

    Out of my Depth

    Cut the pipe level with the subfloor and use a flexi connector to connect to the pan.
  10. P

    Setting correct burner pressure settings on Potterton Suprima 50L

    You wont get any replies unless your gassafe registered.
  11. P

    Potterton Profile 60e System - Pump Runs Continuously

    Pump overrun thermostat stuck .
  12. P

    Bosch Greenstar wiring

    bosch separate them to allow control of external controls, NS is neutral send to external controls, LS is live send to external controls, means the power can be cut when the boiler is switched off, you can also connect pump neutral to the boiler or in the wiring centre, as already said you can...
  13. P

    Nest hot water control on Vaillant Ecotec exclusive 627?

    Look at nest on an s plan, very standard wiring set up.
  14. P

    Valiant ecotech plus 618 boiler - cold pressure 0.9bar. hot water pressure 1.2 bar. Heating and hot water pressure 2.3 bar

    The expansion vessel needs to be recharged, has the boiler been serviced lately ?
  15. P

    Worcester Boiler - Fault has the engineer stumped (video)

    At that age I would be checking the spark generator.
  16. P

    Opentherm with S Plan System

    I have never fitted an ideal boiler so will take your word on the SL1-SL2 ignoring the OT but at least I now know how to run a "plan" with opentherm on any boiler.
  17. P

    Opentherm with S Plan System

    I would fit a separate 240v hot water timer and put a demand on the dhw thermostat/ zone valve connected to sl2, if the boiler stayed on low temp opentherm then short the OT terminals.
  18. P

    Opentherm with S Plan System

    No not sure :) forgot You have to open the dhw zone valve and power the relay.
  19. P

    Opentherm with S Plan System

    Fit an x plan (pdhw with NO zone valve) then you will need a relay to short the OT terminals when hot water is called for, shorting the cables makes the boiler run at high temp, when the relay opens the OT takes control of the central heating.
Back