Search results

  1. P

    How do I get this radiator thing off (pic included)

    if that's the case let the buyer worry about getting the fitting off although I think the op is just being "careful" with money.
  2. P

    How do I get this radiator thing off (pic included)

    Why don't you buy another set of valves rather than using old fittings ? they are that expensive.
  3. P

    Unvented cylinder install - help!

    As already pointed out the valve will be somewhere around the arrow..
  4. P

    Gloworm 30cxi fault

    Was your room stat upgraded when you had the cxi fitted?
  5. P

    Can this Type of Tap be repaired?

    Do NOT put ptfe on the threads.
  6. P

    UVC cooling down very quickly

    I would fit an anti gravity loop off the top of the cylinder after checking the check valve is not stuck open .
  7. P

    Vaillent comby boiler starting when the cold is turned on

    It normally caused by a dead leg on the pipework, have a look at your pipework and see if there are any runs of capped pipes.
  8. P

    Valiant ecoTEC plus 428 - Heating not working

    What is your native language?
  9. P

    Valiant ecoTEC plus 428 - Heating not working

    Turn off the hot water on the programmer, set the d0 to 20 kws and report back.
  10. P

    Valiant ecoTEC plus 428 - Heating not working

    Pumps fine , its on the highest setting.
  11. P

    Valiant ecoTEC plus 428 - Heating not working

    Drop the d0 to 20kws, it wont break or damage your boiler, post a pic of the pump and any buttons or dials on it.
  12. P

    Valiant ecoTEC plus 428 - Heating not working

    And what is a fench icon ?
  13. P

    Valiant ecoTEC plus 428 - Heating not working

    Common problem with these boilers. the pump cant shift enough water through the heat exchanger so the boiler goes into limp mode, what setting is the pump on and what size is it ? you could also try downrating the boiler to 20 kws and see it that helps. (how to is in the install instructions)
  14. P

    Vaillant ecotec 418 F72 F83 faults

    No guarantee they were correct on the suprima.
  15. P

    Vaillant ecotec 418 F72 F83 faults

    Flow and return the wrong way round ? the flow on the suprima is on the opposite side to the vaillant.
  16. P

    Main 24 HE Combi Boiler strange behaviour

    I can hear the parts cannon being loaded.....
  17. P

    Drained system now won’t repressure

    You need to attach a braided hose between the two valves on the pipework under the boiler, the valves have caps on at the moment so the hose should be there somewhere.
  18. P

    Has my boiler's pressure sensor broken?

    It can trap water inside giving a false pressure reading, before you start with “that’s not the op’s problem “ you asked how dirty system water comes into play.
  19. P

    Has my boiler's pressure sensor broken?

    Glow worm pressure sensors have a “hole” in the part that sits in the system water, dirt can block the hole and give wrong readings.