    Vaillant Ecotech Plus No Heating when hot water is on

    You can set the hot water times in the programmer.
  2. P

    Vaillant Ecotech Plus No Heating when hot water is on

    You probably have hot water priority, does your system have weather comp fitted ?
  3. P

    Main combi 24 he, heating always on!

    Main thermistor acts as a frost stat so brings on the heating when the temp drops or it goes out of spec, might be your problem.
  4. P

    Can’t turn heating off

    Either a wiring mistake or you have changed the wrong valve.
  5. P

    Viessmann firing when it shouldn`t

    Might be backfeed voltage from the 3 port keeping the boiler firing but not the pump, I know w/bosch suffer from this and they supply a capacitor fitted across neutral and switched live to cure the problem, not saying this is your problem but cant see what else could be causing it.
  6. P

    Vaillant Ecotec Pro 28 - replaced knob, 0c - no hot water or heating

    Got a thermostat somewhere ? and what happens when you turn a tap on and press i on the boiler.
  7. P

    Move gas cooker leads to ventilation issue

    Yes if you can comply with the dimensions, a ducted extractor fan would be easier and more effective at providing purge ventilation.
  8. P

    Move gas cooker leads to ventilation issue

    If your kitchen is larger than 10 cubic metres you dont need more ventilation (for combustion) the outside door / window is building regs and can be complied with by using a normal kitchen extractor, is does not need to be linked to the cooker as its expected that the user will use it to clear...
  9. P

    Can't figure out how to remove toilet seat

    Does this part unscrew or pull out ?
  10. P

    Baxi smoke tube

    Just as a matter of interest do you have a boiler any where else on the property ?
  11. P

    ALPHA CB28 No central heating ?

    I would strongly suggest you put the boiler back together and get someone that knows what they are doing to fix it, you are going to spend more than a visit from a pro guessing what bit to change next.
  12. P

    Baxi smoke tube

    Unfortunately if the BBU has been removed your fire will be condemned as using the fire on its own is not allowed.
  13. P

    Vaillant boiler - short circuit - pure floor heating

    We dont have your type of system here in the uk, all boilers have to have an interlock (they cant fire unless there is a call for heat) I cant see how your system can work properly without some sort of control between the ufh and boiler.
  14. P

    Vaillant boiler - short circuit - pure floor heating

    Your boiler will run if you remove the weather comp because the 24v link is in place, put the controller back on the boiler, could you tell me how the shunt pump is being controlled ? I am also assuming you have removed the actuator heads from the ufh manifold.
  15. P

    Vaillant boiler - short circuit - pure floor heating

    You cant mix the ebus and 240vac controls without some type of interface, the op needs to tell us how the ufh pump is being controlled ,it could be the ufh actuators taking too long to open and the boiler just dead heading.
  16. P

    Vaillant boiler - short circuit - pure floor heating

    How have you connected the ufh call for heat as it looks like your using vaillants ebus control.
  17. P

    Only get hot water when cold is run

    Might need a tad more information like boiler type, make and model, ect
  18. P

    Main Combi 30 Eco - hot water is cool?

    See is the 22mm central heating pipe on the left under the boiler gets hot when you run a tap, if it does its a sticking diverter valve.
  19. P

    Gravity fed? Potterton 30e/40e , works with Hive

    Can you post a pic of your control set up ? 2 port or 3 port valves ect.
  20. P

    Vaillant ecotec plus 418 Boiler wiring problem

    Here is a vr66 that would do ya.... Preowned Vaillant VRT 350F Wireless Thermostat and VR66 Wiring Centre | eBay