    Has my CH system been flushed correctly?

    Sounds like those two rads and there pipework have not been flushed. What type of flush and amount of time spent flushing will depend on your systems condition. Have they installed a system filter? are there cleaner and inhibitor stickers on the front of the boiler?
  2. B

    Asbestos in artex...

    All asbestos is dangerous, white, brown and blue. White being the lesser risk. I would think one off removal of decorative coatings is a small risk, multipul exposures will be a lot more dangerous. From a legal standing its was your fault and not your dads, its the propertys owner that must...
  3. B

    Gap around boiler flue

    your boilers dangerous if its not been patched outside. dont use expanding foam as some flues are so flimsey they may deform.
  4. B

    Fitting advice for Grohe Tap and new basin

    http://www.toolstation.com/shop/Plumbing/d20/Flexible+Connectors/sd2807/Tap+Tail+Adaptors/p63663 alot of Grohe taps come pre fitted with 3/8 flexi tails, use the above fitting into your iso valves or solder onto pipework.
  5. B

    Polyplumb 18 bar pressure test

    18 bar is standard across polypipes pushfit range from memory, at this pressure it ensures the grab rings bite into the pipe ensuring they cant pop off. Any claim against them and they will ispect fitting and pipe and expect it to have been at 18bar and the ring to have bitten into the plastic...
  6. B

    Installing a stone shower tray

    flexi tile addey can be used. dont use ply on the floors, use cement board like hardi or no more ply. could use tile matting if the sub floor is solid enough.
  7. B

    Wiring after or before new boiler and piping?

    if the pipework is being notched into the joists then they will be a good distance from the part of the joist the sparks is allowed to drill for his cables but its still probably better to do the plumbing first imo.
  8. B

    Logic Code Combi es - are they any good?

    the boilers good. for free its great. make sure the quality of the install is checked as these scheemes tend to have very poor quality work. Companies thend to have the atitude of its free for you so you should be happy even when the works really bad.
  9. B

    External automatic bypass valve on bolier with internal bypass valve.

    apart from giving the appliance its min flow rate (which the internal one may do) fitting one on the system correctly reduces system pressures, reduces noise, increases efficiency and allows the appliance to circulate heat away from itself on over run.
  10. B

    Is solvent weld cleaner needed

    if its a existing stack then cleaner on a strap on boss is a must, if its new stack then you should be fine without cleaner but its still the best option.
  11. B

    Megaflo Dripping Valve

    the strainier will be cleaned on your annual service/ safety check of the cylinder
  12. B

    Boxing in boiler? (moved from forum information)

    put a cupboard around it as access is needed to all parts for service and repair.
  13. B

    samll dent on copper water pipe

    hard to see any dent tbh. where are the pipes installed? if they are being covered over try and lagg them and if needed apply corrosion protection.
  14. B

    Roughly how much to fit gas hob?

    is gas pipe live? is gas pipe sized correctly for new hob? are clearences and ventilation ok (gas regs require certain things an electric hob wont), is a heat barrier needed between hob and draws? theres alot to consider, a straight swap gas for gas with no major alterations would be 45-60...
  15. B

    Waste fitting exiting through wall

    pushfit is fine if fitted well. if you use glued then make sure its upvc as abs is not suitable for outside.
  16. B

    The curious case of the 20mm pipework

    plasson back to blue with a 15mm copper reducing set if you need to cut the black plastic back.
  17. B

    P shaped shower baths,advice please.

    carron, best baths for the money. expect to pay 350-650.
  18. B

    Brass stop tap not fitting well on mdpe stop tap .

    what stop tap was it? assuming by brass it was a compression? best to use a copper insert, tighten up, remove and ptfe the olive a few wraps and refit.
  19. B

    samll dent on copper water pipe

    not normally. post a picture.
  20. B

    Lagging for 22mm pipe

    22x25mm foam lagging and some glue to glue the joints.