  1. G

    speedfit pipe with no inserts....

    The inserts are only there to stop the wall caving in, as mentioned lucky.
  2. G

    CH Zones

    Or the other reason you have 8 zones is you a heating engineer
  3. G

    CH Zones

    whats the size of you house with 8zones. The floor area must be big and more than 3 bed. you have to zone any new FHS or use programmable trvs.
  4. G

    CH Zones

    I can't see the point of a two -three bed house having this set up. This is just a extra cost now and the future. Also, today i installed a 40cdi in a pub/ hotel. there was 65radiators on the system and no zones. (Boiler only for ch - Water feed from andrews ) This complys with building...
  5. G

    CH Zones

    The last couple of FHS i have done been seperating the upstairs and downstairs. A Typical job has 7-8 Rads, I cant see why you have to zone with this number of rads. Whats you thoughts.
  6. G

    Lighting from sockets.

    Yes, You can put a light on the ring as long as it is fused.
  7. G

    white WC soil pipe

    PTS and Plumb centre will be able to order white soil pipe and they will have all pan connectors on the shelf
  8. G

    regulations on radiators in conservatory

    that info was great. i thought it should have it's own independent heating source just could not back this up. the customer will not be happy. don't no what they expect tho a 6m/6m glass building and only could fit a 1000mm rad in.
  9. G

    regulations on radiators in conservatory

    i need some help to find building regs for radiators in conservatory. please help
  10. G

    swa problem

    the swa cables are brown grey black with insulation tape brown blue yellow over the other colours
  11. G

    swa problem

    As i said i stick to my own trade GAS installation, i have part p and my 2330 level 2. I went to collage when i left school which was 6years. if you are not a practicing sparky yes, i would forget loads and i thought part p was covering the domestic side I thought i would get a little...
  12. G

    swa problem

    why do you need building aproval for electrical work. i did not install the cable. i am a gas fitter and that is all i stick to. i have part p but still don't feel confedant to carry out electrical work myself so i will sub it out. i work for a well known energy provider and know 100s of...
  13. G

    master socket and slave

    hello need some help and advice i have a over head incoming phone cable. the first outlet then is the loft- from there landing , hall, bedroom1, kitchen, lunge1, bedroom2, lounge2, and bed3 also from the landing there is a third wire to a hall way then from there to a utiliy yes intotal...
  14. G

    swa problem

    yes, i am going to get someone in to check this cable.Also if reasonable i can afford it the house as i have no paperwork for the electrics and it is all brown and blue cables. lived in the house 4 years and i don't think they harmonized them to long before that. also the swa is only about...
  15. G

    approx 18-20meter ccondence run

    what you think. condence runs internal from loft follows route of chimney approx 6m then under lounge and hall floor approx 12m installed 4years ago and never froze, good workmanship???????????
  16. G

    swa problem

    Isn't this ok because the shed is feed from the fuse board in the house of a 40amp mcb.Then to a separate rcd to prevent nuisance tripping in the house. then from there to the back of the house to a 45amp cooker switch which is next to the door and then carrys on to the end of the house all...
  17. G

    expanding foam

    i cut the foam back and use mortor. it comes to something when they pick faults with this don't you aggree. another 1 was a ncs on a gas pipe that was not sleeved. i said i only have to alter AR --- ID or 2NCS on flues and ventilations that already exist. otherwise just write on...
  18. G

    swa problem

    How can anyone answer that with any accuracy without seeing the details? sorry, i no it's a silly question.I thought people on hear might have a idea,,Price range
  19. G

    swa problem

    its a brick built shed with a metal tile effect roof
  20. G

    swa problem

    main earthing is TN-C-S and it's supplying a garden shed shed fuse board(ring main on a 20amp braker and two lights on a 6amp in shed) house -main fuse board 40amp