Search results

  1. G

    Cannot undo Kitchen Mixer taps - Have bought crowfoot!!

    Your doing something wrong, a box spanner is all that is needed.
  2. G

    Heating AND Water, all on, or all off, only.

    If you have a manual changeover valve (simplicity)then changing the timer for one that has the option of hot water or heating will have been no use to you at all. To have both hot water and heating independently then you will need to have a three way motorized valve fitted in place of the...
  3. G

    shower fitted after tiling?

    Yes, but the pipe work is usually buried in the wall before tiling and at the exact centre for the shower valve, most are 153mm.
  4. G

    registered competant person

    I am registered niceic, never heard of it.
  5. G

    Is microbore OK for combi

    No, unless you have a circulation problem with your existing pipe work.
  6. G

    registered competant person

    Load of balls.
  7. G

    Is my flue dangerous

    The flue has to be at least two metres from the base of the window to the flue terminal to conform to MI's.
  8. G

    Boiler location

    Do away with the expansion tank and have the system converted to a sealed system, using the boiler you have bought.
  9. G

    Need new boiler is this a good price.

    Which Junior is it the 24i or 28i. What about a room thermostat.
  10. G

    towel rail problem

    In your dreams maybe. :lol:
  11. G

    combi boiler

    Keep your existing combi and add an unvented cylinder, no combi is going to supply 3 bathrooms.
  12. G

    Ensuite - will 1.5 metre square suffice?

    http://www.ukhomeideas.co.uk/ideas/bathroom/ideal-standard/ Scroll down to space bathroom, this is normally for the size you require, excluding depth of walls.
  13. G

    What the hell!!!

    Is this a wind up. People who are not corgi registered do gas work very often. :roll:
  14. G

    Kingfisher air consumption spec.

    Those ventilation sizes would be doubled if the air was provided from another room and the room vented direct to outside air, provided that the room is neither a bedroom or bathroom.
  15. G

    Kingfisher air consumption spec.

    Just realised my calculations were wrong, others based on 127kw.....
  16. G

    Kingfisher air consumption spec.

    Requires high level (635cm²) and low level (1270cm²) vents if direct to outside air, ducts should be as short and straight as possible and preferably accessible for internal inspection along the entire length. The situation from your description would mean that the installation would be...
  17. G

    Vaillant 242 leak

    Water valve. Leaks normally from inside components not pipe seals. Easy enough to change complete valve, if you know what you are doing.
  18. G

    pressure and flow

    I was wrong about you, you are just another armchair technical adviser, you should try the real world.
  19. G

    Gas Pipe form Propane Bottles to Hob

    You are welcome to endanger yourself, but please do not encourage others to follow your example of a seriously incorrect installation.
  20. G

    pressure and flow

    I know exactly what he means, you are mincing words again, you pedantic sod :wink: . Bath taps give the appearance of less flow because of the larger bore pipe. Try watering the garden with a 22mm garden hose. :lol: