Search results

  1. lordwoody

    Have to hold in Button for Short flush on Toilet Cistern

    Not sure of the make Gav it came complete with the cistern.
  2. lordwoody

    Have to hold in Button for Short flush on Toilet Cistern

    Yes there are and I have tried adjusting the short flush as per instructions, it is also has it marked on the valve which is which and levels of adjustment but I still have to hold it in!
  3. lordwoody

    Have to hold in Button for Short flush on Toilet Cistern

    I have just fitted a NEW dual flush toilet cistern and to I have to hold in the small button to make a short flush, the longer I hold it in the longer the flush but as soon as I let go it stops. I have tried adjusting the short flush water level slider but it makes no difference. Is this...
  4. lordwoody

    How do I Replace a UPVC Window Sill

    Found some here... http://accringtonplastics.com/3mm-window-board-white.html
  5. lordwoody

    How do I Replace a UPVC Window Sill

    I have looked through there catalogue but cant find anything suitable, can you send me a link on what you mean?
  6. lordwoody

    How do I Replace a UPVC Window Sill

    Thanks I will use something like this..... http://www.truelineproducts.co.uk/over-sills.htm
  7. lordwoody

    Dishwasher Blow Fuse when opening Door

    Thanks Diyisfun It turned out to be a exposed wire which was worn through because of the door opening and shutting then blowing the fuse when water got onto it. Now repaired and working fine :D
  8. lordwoody

    Potterton Starting Problem

    Boiler now fixed it was the PCB again thats the 2nd one Ive had in 3 years!
  9. lordwoody

    How do I Replace a UPVC Window Sill

    Here is my proplem. We are going to have the front upper half of our house weatherboarded using Marley Cedral planks but our existing upvc window sills only protrude 50mm from the wall and the weatherboard protudes 58mm. The sill will need to overhang the weatherboard, so what are my...
  10. lordwoody

    Potterton PCB Differences

    Anyone know what the difference is between a 5111603 and a 5107117 PCB for a Potterton Suprima 60 boiler? And are they interchangeable? They look identical and they both have LMU30.211B159 printed on them.
  11. lordwoody

    Potterton Starting Problem

    My Potterton Suprima 60 is having trouble starting. Its flashes orange then clicks (not ignition clicks) and goes back to continuous orange this keeps going until it eventually ignites. the fan does not run when this is happening. I have had a new PCB 5111603 fitted last year, a new fan...
  12. lordwoody

    See how my house would look software

    Hi Is there any software I can use to see what my house would look like if I had the top half weather boarded? For instance I could upload a photo of my house and add the features to it to see what it would look like. I would like to weather board to top half using Cedral weather board...
  13. lordwoody

    Dishwasher Blow Fuse when opening Door

    Its nearly 5 years old. Its a whirlpool Dishwasher and when the door is opened after a cycle there is a bang and spark that comes from the bottom of the door near the hinge!
  14. lordwoody

    Dishwasher Blow Fuse when opening Door

    Our dishwasher keep blowing the fuse in the plug and triping the CB everytime we open the door after a wash cycle. Any ideas what might be causing this and is there a fix? Thanks
  15. lordwoody

    Flatmaster 2000 vent system

    http://www.condensationshop.com/products/passyfier/sleeved/ Where abouts in Sussex are you?
  16. lordwoody

    Flatmaster 2000 vent system

    No I never fitted one, in the end I opted for a passive De-humidifier vent that does not have any running cost. So far it has cut down the condensation a little but is to early to tell. Cost me around £300 fully fitted.
  17. lordwoody

    Extractor Fan Isolator Switch????

    Oh dear its getting more complicated! Someone has also now told me it will also have to be RCD protected! I am not doing it myself but I am trying to find out the best way to do it without having trunking stuck everywhere (its a 1st floor flat no loft) and to try and stop my tenants turning...
  18. lordwoody

    Extractor Fan Isolator Switch????

    This is the best advise that I think I have had so far...... So basically what he is saying is that the Switched 3A spur would operate the light and the Timer fan and if the Tenant was to switch it off they would be in the dark. I don't suppose anyone could do me a wiring diagram for this...
  19. lordwoody

    Extractor Fan Isolator Switch????

    Would it make things easier if I got the basic model without the timer? Surely the basic model would not require the Isolator switch? just a 3A spur? Like this.... This is the fan manual.... http://www.tlc-direct.co.uk/Technical/DataSheets/Aidelle/ADAUE_Instructions.pdf
  20. lordwoody

    Extractor Fan Isolator Switch????

    Would this be OK it is within Regs as there is a window in the bathroom.