    Gravity fed system for loft conversion - advice please

    Just remember that any sealed system (megaflow type) needs to be installed by a plumber who is qualified in unvented systems, make sure you check his credentials, he spent time and effort and money getting them and will be pleased to show them to you. By the way Megaflow is one of the makes...
  2. P

    Vailant ecotech pro

    At the very least, any condensing boiler should have the condensate trap emptied and cleaned every year, and the combustion exhaust tested. Your boiler has failed its manufacturers warranty by not being given a service history.
  3. P

    Sealed CH System - apparent airlocks in boiler

    Just remember to think about the way the water flows through the boiler, and then make sure that the water that is pushing the sludge is going in the opposite direction to it natural flow so the sludge is sent back into the system and can the be drained out.
  4. P

    Sealed CH System - apparent airlocks in boiler

    You are getting a build up of air because you have an automatic air vent for the hot water but you need one for the heating circuit since that is not using the hot water AAV.That is why the air builds up.
  5. P

    Baxi cutting out

    The reset is usually activated by the overheat stat or repeated failed ignition, so it may be worth replacing the overheat stat anyway since they don't need a drain of boiler at all and only cost about £15-£20
  6. P

    air? pressure old worcester combi boiler s25i old model

    Any rad will do, if you have a drain valve you may be able to do it from there easier if it is not a soldered one that stick closed when heated up.
  7. P

    Baxi cutting out

    Automated analytical equipment for the medical profession.
  8. P

    Baxi cutting out

    I will know more about them when I see them at the moment I can only go by what I am told. I accept that no boiler is going to be perfect, it doesn't have to fly to the moon and back, I always used to recommend Vaillant but now I am not so sure. By the way when you get your email notification...
  9. P

    Baxi cutting out

    As far as I know the only people who have a baxi are tenants, because landlords won't pay for a decent boiler, It may be the pump is not running at full speed, but don't throw any more money at it get rid of it. I am almost completely disillusioned by the unreliability of modern boilers and as...
  10. P

    Radiator issue

    To get the head off wind top until it is fully open then slide the bottom ring of plastic up towards the head then the head will come off. then buy a new head. same make.
  11. P

    What type of hot water system to have?

    Any gas boiler of any type will have the same flue problems, they are given the opportunity of using a plume management kit to help get rid off the exhaust you can get a heating only boiler and if so I would suggest a system boiler then you don't need a tank Intergas make boilers like that and...
  12. P

    air? pressure old worcester combi boiler s25i old model

    You don't need BG if you have no contract with them it is cheaper to get a private gas safe chap go to this site:- http://www.gassaferegister.co.uk/ Type in your post code and choose someone from your area, phone them and see who can come for no call out fee. As Mogget says try with a pair of...
  13. P

    Galaxy Aqua 4000 8.5kW shower problem

    As long as the water pressure going into is ok then it sounds like the temperature control thermostat is faulty. if replaceable try canging that 1st otherwise its the pcb I reckon. javascript:emoticon(':(')
  14. P

    air? pressure old worcester combi boiler s25i old model

    Your filling loop that you use to fill it with water should have 2 taps (isolating vales) on it they should both be opened to fill it then closed to stop filling it. The valve nearest the boiler has a non return valve on it so if both valves are closed and the filling loop is removed completely...
  15. P

    Thorn Olympus 38/50B only heating to 1 degrees then switchi

    Boiler thermostat set at wrong temperature or faulty, room stat set too low or faulty (I know its new one)
  16. P

    Full flow trv's

    Thanks charnwood just what | needed.
  17. P

    Full flow trv's

    Yes nigal but I can only find the body on line not the head.
  18. P

    Full flow trv's

    I have to replace rads in a house and I want to fit full flow trv's on some of the rads and it is a 1 pipe system, so full flow trv's would be best but I don't know who sells them any suggestions would be appreciated.
  19. P

    Thermal Store advice

    I always used to recommend Vaillant, but since the days of condensing I am not so sure anymore, I would now be more inclined towards intergas since they have a good rep for not failing, I am going an a 1 day course with them next month which will give any of their boilers i install a 5 year...
  20. P

    Help please - air in bath and shower hot water

    Try and leave pump running as long as pump strainers are clear and hot and cold water work elsewhere, a hose may clear the air lock, as soon as it clears the pump will take over and you will know. So be ready.