  1. P

    Circuit breaker problem

    AIUI the problem with immersions is you have a very large screw thread in a relatively thin tank with the result that sometimes attempting to unscrew the immersion can tear the tank, at which point you have a large emergency plumbing problem on your hands.
  2. P

    Earth funnies and phantom voltages on lighting circuit

    Interesting article, I'd guess some style guide required an image on every article and some non-expert skimmed the article and tried to draw one up.
  3. P

    Earth funnies and phantom voltages on lighting circuit

    I don't know where precisely that image came from, but it happens all too often that a supposedly reputable oganisation puts out content written by some hack who doesn't know what they are talkig about. Does anyone remember the shining turd that was the IEC "world plugs" page. If they can't...
  4. P

    Cut into live mains cable with metal stanley knife..

    IIRC if the situation with the cutout is deemed unsuitable for live-working they will usually dig up the service cable and cut it to isolate the cutout.
  5. P

    Important information Preparing for a power cut.

    For works done "dead" I would think the phases of a work most likely to cause "more disruption than planned" would be when you try to disconnect a section and/or re-route power and/or move customers onto generator supplies at the start of the works, and when you try to re-energise that section...
  6. P

    Important information Preparing for a power cut.

    But concentrated on the hours when planned works happen, and particularly the hours in which planned works start and end and hence network switching operations are performed. I very much doubt that if you plot unplanned outages VS time of day you will see a uniform distribution, but what the...
  7. P

    Important information Preparing for a power cut.

    I expect that some are more random than others. There will be failures due to random events sure, but there will also be failures due to overloading (which I'd expect to happen either in the morning when people go to work, or around teatime when they come home) and failures due to planned works...
  8. P

    Important information Preparing for a power cut.

    I think the problem is it's hard to give specific advice when peoples circumstances are so widely variable. Do they live urban or rural? Do they drive? What is their budget? Money no object - solar system with batteries and islanding capability to maintain power. Starlink to maintain...
  9. P

    reconnecting the electric from a demolished building

    Basically anything electrical, is the "service head" and meter still there? if not is there a largeish cable somewhere that looks like it has been "capped off"? or a run of wires on poles? Note: in the UK wires carrying domestic mains voltage on poles are usualy either bunched or stacked...
  10. P

    Wago

    Neither the 221 or the 222 series of lever terminals have a four-position connector. They do offer some four position push-ins though.
  11. P

    Wago

    Wago terminals are designed for a single conductor per hole. Doing otherwise would be going "off-label". Now I don't think there is anything in the UK that outright forbids going off-label (heck for many years we all used terminal block that came with bugger-all in the way of labelling or...
  12. P

    Interesting.

    Not sure what you think was "strange" The sharing of current is proportional to the cross-sectional area of the conductor but the surface area of a conductor is proportional to the sqaure root of the CSA. So with conductors in paralell the larger conductor will tend to overheat first. I would...
  13. P

    Quick question

    The (recently discontinued) "schnider lisse" range of switches came with a loop terminal (or sometimes multiple loop terminals) to park your neutrals in. Not sure if any ranges still in production do.
  14. P

    Concrete post tilted. Gap in fence

    I don't know if it's "proper" but the soloution my parents and I have used to this sort of problem is to screw/nail extra wood to the fence panel to fill the gap.
  15. P

    Does LED bathroom mirror require fused spur?

    In your particular case no. BS7671 nowadays specifies (with some exceptions) a maximum protective device rating for ES/BC/SES/SBC lampholders of 16A. It doesn't specify anything in particular for light fittings without user-replacable bulbs, but in the absence of other instructions from the...
  16. P

    If the electricity company's neutral gets disconnected at the meter or somewhere outside the house

    I suspect some confusion is coming from the fact that probablly more than half of the people on the english speaking internet are americans. In TN-C-S systems in the UK, then neutral and earth split at the service head, *before* the meter. So in the UK a lost neutral at the meter will not...
  17. P

    Consumer unit - If i need to change a light pendant Will turning off the one switch be enough?

    It substantially reduces the risk of inadvertent re-energisation, either from someone who doesn't understand why the switch is off, or from someone or something bumping into the switch.
  18. P

    Switched fused spur with cable outlet and USB port?

    If your ok with it sticking out of the wall you could use a single to double converter box. e.g...
  19. P

    Switched fused spur with cable outlet and USB port?

    hmm, good question, I thought you could but I can't seem to find one. However, there is an alternative, Scholmore sell a double plate that is half gridpro and half Euro module, and gridpro does have a flex outlet module. There are single width USB charger modules. So the full list would be...
  20. P

    Cooling the home, are these costs real?

    Typical "portable ACs" with a single flexible hose are inefficient for serveral reasons. 1. The refrigeration machinery (which makes heat) is inside the room. 2. They use room air to cool the "hot side", which is then exhausted. This room air must be replaced by outside air leaking into the...