Search results

  1. S

    steel beam

    I've fitted a steelbeam which is a 6mm steel box section 150wide x 250 high with a 10mm plate 250mm wide welded to the bottom over my bi fold doors at a rear lean to extension.The beam is 5m long and i've sat it on a padstone at each end ,the beam is parallel with the wall so the box section...
  2. S

    below damp?

    Did you still put dpc along the brick on edge and if you did,did you lap it up into the 3rd course dpc?
  3. S

    below damp?

    Hi there, does anyone know wether you can take a course of bricks out below damp to fit aluminium bifold doors so that there is no step?
  4. S

    extension above garage

    Good suggestions.The reason is is the electric consumer unit is on the garage wall and the new boiler is in the utility room.The garage has a hipped roof and the utility has a flat roof at the back of the garage roof.My idea was prop the trusses up around garage and prop joists up at back of...
  5. S

    extension above garage

    Hi there,going to start extension above garage in next couple of months but heres the problem i have to take garage roof off and the utility which backs onto the garage roof off aswell.Is there any way i can leave roofs on while building up till i get main roof blacked in.Thinking of acroing...
  6. S

    roof span

    its a shallow pitch aswell maybe 20 degrees.is there a certain height the collar ties must be placed.
  7. S

    roof span

    its just i read that over 6m in span it had to be trusses with girder truss and mono trusses.is there extra precautions you have to take with traditional hip roof at that span.
  8. S

    roof span

    Could anyone tell me if you can build a traditional hip ended roof that has a span of 6 metres.thanks.
  9. S

    hipped roof

    hi there,building an extension approx 6m x 4m putting a hipped roof on it.i,m a joiner but i haven't done alot of cut roofs just alot of trusses.what size timber should i use for the rafters and hips also whats the best way to fix the ridge to the house.any help appreciated.
  10. S

    lean to roof

    Yes! Purchased today.
  11. S

    lean to roof

    How do i go about marking the rafters?
  12. S

    lean to roof

    How do i go about marking them out? Why 400 centres? Will be putting a couple of velux windows in aswell.Do this make a difference?
  13. S

    lean to roof

    Span will be about 3.5m not sure about pitch.
  14. S

    lean to roof

    The tiles will be marley modern interlocking tiles.What size pitching plate should i use? Will 6"x"2" be ok for the rafters?
  15. S

    lean to roof

    Could anyone tell me how to construct a lean to roof.you've got a wall plate on top of the block and a 4"x1" plate along the wall,how do you mark the rafter(the plumb cut and birdsmouth).any help appreciated.
  16. S

    blocking chimney

    Will i still have to provide ventilation if i cap the chimney off?
  17. S

    blocking chimney

    Removing my existing fire and want to block it up.I've heard that you need to put a vent for airflow where the fire was.I was wondering instead of putting a vent on the inside of the house could i not put an airbrick on the outside of the chimney.Help appreciated.
  18. S

    wimpy joiners

    Sorry i meant George Wimpy the housebuilder.
  19. S

    wimpy joiners

    Any wimpy joiners use this forum?
  20. S

    marking rafter

    howdy.working on a new building site for a different house builder.putting on a roof i've never done before.the top hat trusses sit on two gluelam beams which are easy enough but how do you you mark the 7x2 which gets fitted from the side of the top hat to the wallplate any help would be great.
Back